Range Hood Care
Range Hood Care
Cleaning
IMPORTANT: Clean the hood and baffle filters frequently according to the
following instructions. Replace the baffle filters before operating the hood.
Exterior Surfaces:
To avoid damage to the exterior surface, do not use steel wool or soap-
filled scouring pads to clean the hood.
Always wipe dry to avoid water marks.
Cleaning Method:
•
Liquid detergent soap and water or all-purpose cleanser
•
Wipe with a damp soft cloth or nonabrasive sponge, then rinse
with clean water and wipe dry.
•
Do not use cleaning agents containing bleach.
Stainless Steel Baffle Filter:
1. Remove the filter by pulling the spring release handle, and
then pulling down the filter.
A. Spring release handle
2. Wash the stainless steel baffle filter as needed in your dishwasher
or a hot detergent solution.
3. To reinstall the filter,first make sure the spring release handles are
toward the front. Insert the stainless steel filter into the
upper track.
4. Push in the spring release handle.
5. Push up on the stainless steel filter, and then release the handle to
latch the filter into place.
WARNING
When removing the filter, please hold it with both hands to make sure it
does not fall.
Replacing an LED Lamp
The LED lights are replaceable by a service technician only. See the
support contact information in the Warranty section.
Accessories
NOTE
When used in recirculation mode, To Reduce the Risk of Fire and Shock
use only conversion kit Models:
Recirculating kit: NK-AF030FNB/AA
Charcoal filter replacement: NK-AR050FNB/AA
Recirculating kit
1. Assemble the air deflector with the duct cover bracket using four
4.2 x 8 mm screws.
2. Measure from the bottom of the air deflector to the bottom of the hood
outlet.
3. Cut the duct to the measured size "X."
B
D
E
A
4. Remove the air deflector.
5. Slide the duct onto the bottom of the air deflector.
6. Place the assembled air deflector and duct over the exhaust outlet
from the hood.
7. Reassemble the air deflector to the duct cover bracket with the four
assembly screws.
8. Seal connections with vent clamps.
To replace charcoal filter:
NOTE
The maximum BTUs if you use carbon filter is 46 000. If you use the hood
with the carbon filters on and it does not decrease the BTUs the engine
can fail or generate an unsafe act.
1. Cover the grille that covers the blower motor with the charcoal filter
so that the slots on the filter correspond to the pins on the sides of
the motor grille.
2. Turn the charcoal filter clockwise to lock it.
3. Repeat steps 1-2 on the other filter.
A
B
A. Assembly screws
B. Air deflector
C
C. Duct cover bracket
A
X
C
A. Air deflector
B. Vent clamp
C. X = length to cut vent duct
D. Vent duct
E. Exhaust outlet
C
A
B
A. Charcoal filter
B. Pins
C. Blower motor
English
11