Descargar Imprimir esta página

RIB R50 ICE Manual Del Usuario página 38

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

G
B
DIP 1 ON (hold-to-run mode)
Or failure of a safety device
DIP 2 ON (full stroke programming)
DIP 2 ON > DIP 1 ON (pedestrian stroke programming)
Programming sequence stopped due to intervention of a safety device
No transmitter code entered
DIP 1 ON > DIP 2 ON - transmitter code programming for full opening
DIP 1 ON > DIP 3 ON - transmitter code programming for pedestrian opening
DIP 1 ON > DIP 2 ON > DIP 3 ON - transmitter code programming for R-AUX relay
Correct transmitter codes programming for full opening and R-AUX relay
Correct transmitter codes programming for pedestrian opening
Remote control code not present in memory
Memory saturated by remote control codes (1000 codes saved)
Radio code deletion for full opening, pedestrian opening, R-AUX relay
Stop button pressed
Photocell intervention
Edge intervention
Failure of a safety device or safety device engaged for too long
Alarm from edge
Failed photocells auto-test alarm
Functional block activated by smartphone
Achievement of set cycles
Energy saving activated by smartphone
FAULT
After having carried out the various connections and having supplied
voltage, all the LEDS are switched OFF.
The motor opens and closes, but it has no strength and moves slowly.
The gate opens but does not close after the time set.
The gate does not open or close by activating the various START, RADIO,
OPEN and CLOSE buttons.
The electric lock does not work.
The buzzer emits 2 long tones and the gate does not move
The remote control does not work. Led DL12 lit red
TABLE SUMMARISING VISUAL AND SOUND ALARMS
SIGNALS DURING PROGRAMMING SEQUENCE
EVENT
EVENT
WARNING SIGNALS DURING OPERATION
EVENT
On the board there are resettable fuses which intervene in the event of a short circuit, interrupting the output
assigned to them.
In the event of troubleshooting, it is advisable to disconnect all the removable connectors and insert them one at a
time in order to more easily identify the cause of the fault.
Check the integrity of fuse F1. If the fuse is blown, use only a suitable replacement.
F1 = T 5A MOTOR PROTECTION FUSE
Check trimmers TORQUE and LOW-SPEED adjustment.
Make sure that the TCA trimmer is activated with LED DL6 ON.
B.I.O. contact always on => check the status of the clock connected to B.I.O..
Photocells Auto-test failed => check the connections between the control panel and the photocells.
Stop, Edge or Photocell with DIP 4 OFF contact fault => Fix or replace the faulty contact.
Photocells Auto-test failed => check the connections between the control panel and the photocells.
Ensure to have enabled DIP 8 to ON.
Check the cable.
Safety edge with 8,2 KΩ resistor. Remove the resistor or configure the EDGE input via the RIB GATE app
Lack of radio module in connector J5 or faulty radio module.
BUZZER STATUS
OFF
OFF
OFF
10 s tone with 2 s pause
BUZZER STATUS
OFF
OFF
OFF
OFF
1 Tone
1 Tone
OFF
OFF
2 Tones
BUZZER STATUS
OFF
1 Tone
2 Tones
OFF
2 Tones every 5 s for 1 minute
(It is renewed by giving a command)
4 Tones every 5 s for 1 minute
(It is renewed by giving a command)
OFF
6 Tones every 5 s
(It is renewed by giving a command)
OFF
SOLUTION
38
FLASHER STATUS
DL1 LED STATUS
OFF
Flashes ON/OFF 250 ms
OFF
Flashes ON/OFF 500 ms
OFF
Flashes ON/OFF 500 ms
OFF
On steady
FLASHER STATUS
DL12 LED STATUS
OFF
Flashes red/green
OFF
Flashes red for 10 s
OFF
Flashes green for 10 s
OFF
Flashes orange for 10 s
OFF
Turns green once
OFF
Turns red once
OFF
Red flash
OFF
Runs 6 green flashes
OFF
Runs 2 green flashes
FLASHER STATUS
LED STATUS AND SIGNAL OUTPUT
OFF
Led DL6 turns OFF
OFF
Led DL7-8 turns OFF
OFF
Led DL9-10 turns OFF
OFF
Led DL1 flashes ON/OFF 250 ms
Flashes for 1 minute
No led combined
OFF
No led combined
OFF
Led DL12 is steady on green.
OFF
No leds matched
OFF
Blue led flashes once every 5 s

Publicidad

loading

Este manual también es adecuado para:

R50B2-crxAa21580Aa21581