Cordivari Heat Manager is a thermostat designed to work with a
temperature sensor that communicates information in real time; this
information is used to manage the auxiliary heating of the water storage
in which it is installed, according to the user's preferences. In this regard,
the user can choose to manually switch the device on after setting
the desired temperature or can program the switching on by selecting
specific time slots and setting the relevant desired temperature. In
addition, the user can also view the measured temperature trend, the
status of the electric heater during the recorded period, and download the
data for the last week. Cordivari Heat Manager allows to optimise power
consumption by programming device switching on only when necessary.
Cordivari Heat Manager, when installed in combination with solar thermal
systems, also allowsto optimise the use of renewable sources, such as
solar energy, and avoid the consumption of energy from fossil fuels when
not necessary. Whether you would want to have, for an higher energy
request than that the system is able to produce with only the primary
solar power, a storage always at the right temperature, it is necessary
to complete the operation of the system with the use of auxiliary heating
elements, more so, if the solar power is the only source for the production
of domestic hot water.
Once the optimum storage temperature has been set, and this is at a
higher value than the set one, the heating element will not ignite avoiding
unnecessary power consumption. Program the device according to your
own needs, to ensure that the heating element switches on approximately
2 hours before the consumption of domestic hot water.
If the domestic hot water is mainly used in the evening, program the
device so that the heating element is switched on in the late afternoon; if
the storage is already at temperature, it will not be supplied.
It is important to use the device by giving priority for its operation to
renewable energy sources.
• Program the switch-on/off logic of the auxiliary energy
sources by giving overall priority to renewable sources
• In order to avoid unnecessary energy and resource
waste, ensure that auxiliary energy source switch-
on/off programming has been correctly completed
by analysing energy consumption of the days
immediately following device installation
• The device has an IP20 protection rating. Therefore, it
is not suitable for outdoor installations. Install it inside
an electric panel or inside an IP55 rated enclosure.
2. Specifications
User manual
616 mm
451 mm
4220 mm
Temperature measurement
range
Temperature setting range
Temperature accuracy
Clock
Programmes
Hysteresis
Relay features
Power supply
WiFi unit power
WiFi features
Operating temperature
Storage temperature
Operating humidity
IP protection rating
Main fuse
WiFi fuse
Overvoltage category
Security
Type of communication
3. Safety instructions
The end user is the sole responsible for the use of the product and for
any damage caused to third parties.
Take the utmost care when using the product and its accessories, keep
them in a clean and dry place, away from dust.
Do not expose the product and its accessories to fire or near heat
sources. Prevent the product from being hit or mechanically damaged.
Do not use harsh chemicals, detergents or cleaning sprays. Do not
attempt to disassemble the product or its accessories; this operation can
only be performed by qualified personnel. The operating temperature of
the device ranges from 0°C to +45°C and the storage temperature from
-20°C to +60°C. To dispose of the product at the end of its life, follow the
national and regional indications.
The device must be installed inside electric panels or inside suitable
containers.
Any change to the product is strictly prohibited.
The device operates with a supply voltage of 100-240 V AC at 50/60
Hz. For repairs, use original components only. The use of non-original
components could cause serious damage. In case of malfunction,
immediately power the device off. Do not use the device with damaged
cables or connectors. Should the electrical connections be damaged,
- 10 -
-55°C to +125 °C (0.1 °C)
-55°C to +100 °C (0.1 °C)
±0.5°C (da -10°C to +85°C)
NTP Internet, accuracy up to 100 ms
Mode
ON/OFF
Weekly programming
Manual temperature setting
0°C to ±75°C (0.1 °C)
Max 230V˜; 16A
(4A inductive load)
100-240V˜; 50/60 Hz; 35 mA; T45
<5W
WiFi b/g/n/ 2.4 GHz
0°C to +45°C
-20°C to +60°C
5%
to
90%
in
the
absence
condensation
IP20
FF1 T 250mA 250V 35°
F1 IH 0.30° EN 0.60° U 30V Imax 10°
0.1 s max
II
SELV
Wireless
Cod. 1910000002121 - nv01