have them repaired by a qualified professional.
Do not leave children near the device without the supervision of an adult.
Do not allow children to play with the device since they are not able
to properly assess the hazard resulting from an electrical risk. Store
and use the device in a dry place, duly protected from liquids that could
originate a short circuit.
4. Installation
Remove the central unit and the temoerature sensor from the box.
• Before device installation, disconnect the power
supply. In any case, the operations must be carried
out by a qualified installer.
• Do not modify or damage the protective plastic
enclosure of the device.
The device can be used to control the power supply of heating systems
that allow power supply interruption through a normally open or normally
closed circuit. Connect the power supply to the connectors marked with
N and L in the figure.
Connect the device you want to control to the connectors marked with
NO and COM in the figure; in this way the connection to the relay is
made in normally open mode. The sensitive element of the temperature
sensor must be placed inside the storage through the use of a dedicated
probe holder.
Connect the power cable to the device using the screws on the terminal
board in order to insert the terminals inside the special housings.
N
L
N
L
Cod. 1910000002121 - nv01
100-240 V~
50/60 Hz
35mA T45
L
N
N
L
NC
NA
C O M
The product is designed for installation in areas with limited access such
as electric panels or boxes with high IP protection rating.
4 .1 . Creating a Cordivari account
To create a Cordivari account, open www.cordivariheatmanager.com and
click on login. Now you have to register in order to configure and use the
device. Click on "Register", fill in the required fields during the registration
process and click on "register".
Now you can connect the device to the network and configure it.
E-mail*
Password*
LOG IN
Forgot password?
Login With Facebook
Login With Google
4 .2 Connecting the device
Connect the temperature sensor: use the connector on the cable and
insert it into the appropriate housing. To make the connection, remove the
plastic protective cover from the device. Once the sensor is connected to
device body, put the plastic protective cover back into place.
Device correct operation is ensured by connecting it to a network with
internet access
.
Bollitore
The device supports 2.4 GHz WiFi network.