GB
IE
enced electrician and meet the
requirements of IEC 60364-1.
• The device must only be con-
nected to a mains socket via a
residual-current circuit breaker
(RCD) with a rated leakage cur-
rent of not more than 30 mA.
Fuse: at least 13 ampere.
• Before each use, check the
equipment, cable and plug for
damage.
• If the power cable for this
equipment is damaged, it must
be replaced by the manufac-
turer, a customer service agent
of the same or a similarly quali-
ied person in order to prevent
hazards.
• Do not pull the plug from the
socket by the cable. Protect the
cable from heat, oil and sharp
edges.
• Do not carry or ix the equip-
ment by the cable.
• Use only extension cables that
are protected from spray water
and designed for outdoor use.
Always fully unroll a cable
drum before use. Check the ca-
ble for damage.
• Before any work on the equip-
ment, during work breaks and
in the case of non-use, remove
the plug from the socket.
• The cross-section of the power
supply cable must not be less
than 2 x 2,5 mm².
• Wear sturdy footwear to protect
against electric shock.
22
Initial Operation
In keeping with current regulations
a pressure washer must never be
operated off the drinking water
mains supply without a controlla-
ble backlow preventer. A suitable
backlow preventer in conformity
with EN 12729 type BA must be
used.
Water that has passed through a backlow
preventer is classiied as undrinkable.
A backlow preventer is available
from specialist retailers.
A system separator (check valve) prevents
the backlow of water and detergent into
the drinking water pipeline.
•
Employ an ordinary garden hose for
the water intake and ensure suficient
length.
Setting up
•
Slide the holder for the detergent
B
tank / mains cable (16) to the
into the receptor on the applian-
ce side.
•
Slide the holders for the steel
tube (14) into the receptors on
the back side.
•
Slide the holders for the steel
tube (9) into the receptors on the
back side.
•
Slide the holder for the spray
gun (5) to the into the receptor
on the front side.
•
Remove the nozzle cleaning pin
(6) from the rear fold-out side of