Descargar Imprimir esta página

Parkside PHD 110 B1 Traduccion Del Manual De Instrucciones Originale página 22

Limpiadora de alta presión

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 69
GB
IE
enced electrician and meet the
requirements of IEC 60364-1.
• The device must only be con-
nected to a mains socket via a
residual-current circuit breaker
(RCD) with a rated leakage cur-
rent of not more than 30 mA.
Fuse: at least 13 ampere.
• Before each use, check the
equipment, cable and plug for
damage.
• If the power cable for this
equipment is damaged, it must
be replaced by the manufac-
turer, a customer service agent
of the same or a similarly quali-
ied person in order to prevent
hazards.
• Do not pull the plug from the
socket by the cable. Protect the
cable from heat, oil and sharp
edges.
• Do not carry or ix the equip-
ment by the cable.
• Use only extension cables that
are protected from spray water
and designed for outdoor use.
Always fully unroll a cable
drum before use. Check the ca-
ble for damage.
• Before any work on the equip-
ment, during work breaks and
in the case of non-use, remove
the plug from the socket.
• The cross-section of the power
supply cable must not be less
than 2 x 2,5 mm².
• Wear sturdy footwear to protect
against electric shock.
22
Initial Operation
In keeping with current regulations
a pressure washer must never be
operated off the drinking water
mains supply without a controlla-
ble backlow preventer. A suitable
backlow preventer in conformity
with EN 12729 type BA must be
used.
Water that has passed through a backlow
preventer is classiied as undrinkable.
A backlow preventer is available
from specialist retailers.
A system separator (check valve) prevents
the backlow of water and detergent into
the drinking water pipeline.
Employ an ordinary garden hose for
the water intake and ensure suficient
length.
Setting up
Slide the holder for the detergent
B
tank / mains cable (16) to the
into the receptor on the applian-
ce side.
Slide the holders for the steel
tube (14) into the receptors on
the back side.
Slide the holders for the steel
tube (9) into the receptors on the
back side.
Slide the holder for the spray
gun (5) to the into the receptor
on the front side.
Remove the nozzle cleaning pin
(6) from the rear fold-out side of

Publicidad

loading

Este manual también es adecuado para:

300221