3.4.1. Alarm Activated by Keypad (type 1) and Alarm Activated by External Output (type 2)

The microphone base has the feature of providing an audio alarm signal that can be
transmitted throughout the whole installation or to selected groups only.
There are two different types of alarm: type 1 alarm is activated at the microphone base key
pad by simultaneously pressing keys 7, 9 and 0; type 2 alarm is activated by means of an
external signal connected as shown in the wiring diagrams
(2.1.2. for New 100 Series installations and 2.2. for 400
Series installations).

3.4.2. Selecting the Alarm's Audio Signal

Types of audio signal tone
To select type 1 or 2 audio alarm
signal tone, key in 942 or 945
respectively followed by the PRG
button.
Define the type of audio signal (1, 2, 3) or key
in 0 to deactivate type 1 alarm.
Press the PRG button to confirm.
Adjusting the volume level
To adjust type 1 or 2 audio alarm
signal volume level, key in 941 or
944 respectively followed by the
PRG button.
Key the desired sound level between the
values of 0 (minimum) and 50 (maximum).
Press the PRG button to confirm.
7
Alarm
0
9
4
2
ALARM 1 TONE
9
4
5
ALARM 2 TONE
PRG
PRG
1
A- 1
PRG
PRG
9
4
1
ALARM 1 LEVEL
9
4
4
ALARM 2 LEVEL
PRG
PRG
2
9
29
PRG
PRG
3. User Manual

3.4. Alarm Generator

In both options the microphone base generates a
characteristic audio signal for each type of alarm
(see 3.4.2.) and sends it to the group address
programmed (see 3.4.3.). By default the alarm
signal is transmitted to all control units, as if it
were a general transmission (address=0).
9
In both cases, the alarm signal is terminated when
the TALK button is pressed.
3.4.3. Destination Address of Alarm
Signals (only 400 Series)
To select the address to receive a type 1 or 2 alarm signal,
key in 943 or 946 respectively followed by pressing the
PRG button.
Define the group number (between 0 and 250) for the 400
Series and between 0 and 10 for the New 100 Series)
which is to receive the alarm signal.
To have all areas receive the alarm key in address 0.
9
4
3
ALARM 1 ADDRESS
9
4
6
ALARM 2 address
PRG
PRG
0
Press the
0
PRG button
PRG
PRG
to confirm.