EPS-100W.book Seite 17 Donnerstag, 19. August 2010 1:21 13
CoolPower EPS100
5
Technical description
The mains rectifier can operate all coolers and refrigerators with BD35F com-
pressors at 230 V. With a 230 V mains connection, the rectifier automatically
switches from battery to mains operation.
When disconnected from the 230 V mains supply, the rectifier automatically
switches back to battery operation. Mains operation via the rectifier always
takes priority over battery operation.
5.1
Control elements
Item in
fig. 1, page 3
1
2
3
4
5
6
7
6
Mounting the mains rectifier
If you wish to mount the mains rectifier in a fixed position, please observe the
following mounting instructions:
Do not mount the device
– In wet or damp environments
– In the vicinity of combustible materials
– In areas where there is a danger of explosions
The place of installation must be well-ventilated. A ventilation system
which is at least equivalent to the air openings in the device must be
present for installations in closed housings.
Explanation
Mains cable
Fastening bracket
Self-tapping screws
12 V socket
Glass fuse (250 V, 4 A, slow-blow)
Compressor output terminals
Battery input terminals
Technical description