EPS-100W.book Seite 18 Donnerstag, 19. August 2010 1:21 13
Using the mains rectifier
The air intake on the underside or the air outlet on the back of the device
must remain clear.
The installation surface must be level and sufficiently sturdy.
➤ Secure the mains rectifier with the fastening bracket (fig. 2, page 3).
7
Using the mains rectifier
Warning!
Do not reverse the polarity. If the poles are reversed device may
overheat and be damaged.
Caution!
Replace defective fuses with new ones of the same rating (4 A
slow-blow).
➤ Fit wire sleeves to the ends of wires which you wish to connect to the
mains rectifier.
Note
To avoid drops in voltage and therefore performance, keep the ca-
ble route as short as possible and only disconnect it when neces-
sary.
➤ Determine the required cross section of the cable in relation to the cable
length according to fig. 5, page 4.
Key for fig. 5, page 4
Co-ordinate axis
l
∅
➤ Connect the battery using the B+ and B– terminals on the front plate
(fig. 3, page 3).
➤ Connect the BD35F compressor
– using the C+ and C– terminals (fig. 4 1, page 3) or
– using the socket on the front plate (fig. 4 2, page 3).
18
Meaning
Cable length
Cable cross section
CoolPower EPS100
Unit
m
mm²