Hayward Pool AquaRite + Manual Del Usuario página 38

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Electrolysis
1
OK
6
OK
3
Enter the Service menu from the configuration menu
4
Enter the password:
5
Choose the cell model corresponding to the one that is
installed.
6
Electrolysis: Electrolysis function programming.
7
Level: Chlorine production (gr/h) required.
Filtration
1
OK
5
+
-
6
Heating (Option available with the temperature
probe)*: This mode acts in the same way as the
automatic mode, but it can also operate via a relay that
controls the temperature. The set point temperature is
determined in this menu and the system operates with
a hysteresis of one degree (for example: if the set point
Page 16 of 21
2
7
8
Cover: Closed cover safety activation.
Reduction: % of chlorine production when the cover is
closed (20% by default).
9
Boost (Super Chlorination): Filtration and continuous
production of chlorine for 24 hours (maximum
production level).
Automatic return to the filtration and production mode
programmed after the 24 hours.
2
+
-
6
+
-
temperature is 23°C, the system will start up when the
temperature falls below 22°C and shut down only when
it rises above 23°C).
Heating control OFF: The heating operates only during
the filtration periods configured.
USE ONLY GENUINE REPLACEMENT PARTS
AquaRite +
3
OK
8
3
4
7
+
-
4
OK
9
OK
Note: the device can only control the operation of the
filtration pump if the pump is connected to the "Filter
Pump" relay.
10
During the boost period, redox control (option) can be
deactivated.
1
Filtration modes.
2
Manual: Allows the filtration process to be turned on
and off manually.
3
Filter cleaning: This mode is used to backwash the
filter.
4
Automatic: In this mode, filtration is turned on
according to the start and end times set in the time
slots. The time slots always operate on a daily basis.
5
Smart*: This mode is based on the automatic mode,
with its three filtration intervals, but the filtration times
are adjusted according to the temperature. This is
done by setting two temperature parameters: the
maximum temperature, above which the filtration
times will be determined by the time slots, and the
minimum temperature, below which filtration will be
reduced to five minutes, the minimum operation period.
Between these two temperatures, the filtration times
will be staggered linearly. The antifreeze mode can be
activated to turn the filtration on if the water temperature
falls below 2°C.
Heating control ON: Keeps the filtration on after
the filtration period has expired if the temperature is
below the set point temperature. When the setpoint
temperature is reached, the filtration and heating stop
and only resume when the next programming period
begins.
5
10
Rev. B

Hide quick links:

Publicidad

Tabla de contenido
loading

Productos relacionados para Hayward Pool AquaRite +

Tabla de contenido