Disposing of dust
CAUTION:
Empty the cleaner before it
becomes too full, or the suction force weakens.
CAUTION:
Be sure to empty the inside of the
cleaner itself of dust. Failure to do so may cause the
filter to be clogged or the motor to be damaged.
Disposing of dust for normal filter
In order to drop dust sticking on the filter in the capsule,
tap the capsule 4 or 5 times with your hand.
► Fig.8: 1. Capsule 2. Suction inlet
Point the suction inlet downwards, turn the capsule in
direction of the arrow as illustrated, and disconnect the
capsule slowly and straight.
► Fig.9: 1. Capsule 2. Suction inlet
NOTE: Be sure to set a garbage bag beneath the
capsule, as dust may spill out when the capsule is
opened.
Remove accumulated dust from inside of the capsule
and off of the prefilter.
► Fig.10: 1. Prefilter 2. Capsule
Twist the prefilter in direction of the arrow to unfasten
the securing lip from the cleaner unit and then pull off
the prefilter.
► Fig.11: 1. Prefilter 2. Securing lip
Clean out fine dust from the prefilter. And then, pull off
the filter and lightly tap it to remove dust.
► Fig.12: 1. Filter 2. Prefilter
Disposing of dust for high
performance filter
In order to drop dust sticking on the filter in the capsule,
tap the capsule 4 or 5 times with your hand.
Now point suction inlet downwards, turn capsule in
direction of arrow in diagram, and disconnect capsule
slowly and straight.
► Fig.13: 1. Capsule 2. Suction inlet
NOTE: Dust may spill out when capsule is opened, so
be sure to set a garbage bag beneath capsule.
Remove accumulated dust from inside of capsule and
off of high performance filter.
► Fig.14: 1. Capsule 2. High performance filter
Twist high performance filter in direction of arrow to
unfasten securing lip from cleaner unit and then pull off
the filter.
► Fig.15: 1. Securing lip
Clean out the fine dust and lightly tap to dislodge dust
from high performance filter.
Reassembly
Reassembly for normal filter
Put on the filter fully in position on the cleaner unit.
► Fig.16: 1. Filter
NOTICE:
Make sure the filter is put on straight
without being peeled back. If the filter is put on
incorrectly as illustrated, dust will get into the motor
housing, and cause a motor failure.
► Fig.17: 1. Filter
Install the prefilter. At this time, make sure to twist the
prefilter so that the securing lip is firmly locked in the
cleaner unit.
► Fig.18: 1. Prefilter 2. Securing lip
► Fig.19
Install the capsule. Align the mark on the capsule with
the mark near the handle and then firmly twist the cap-
sule in direction of the arrow until it is secured.
► Fig.20: 1. Capsule 2. Handle 3. Mark
NOTE: Always remove dust ahead of time, as the
suction power will be reduced if there is too much
dust in the cleaner.
NOTICE:
Always be sure to check that both the
filter and prefilter are loaded correctly prior to
using the cleaner. If they are not loaded correctly,
dust will get into the motor housing, and cause a
motor failure. If the following examples occur, the filter
and prefilter are not loaded correctly. Reload them
correctly to rectify problem.
Problem Examples
Example 1: Only the prefilter has been loaded (no filter)
► Fig.21: 1. Prefilter
Example 2: Only the filter has been loaded (no prefilter)
► Fig.22: 1. Filter
Example 3: The filter has been loaded in a peeled back
state
► Fig.23: 1. Filter
Example 4: The securing lip on the prefilter is not firmly
locked in the groove of cleaner housing
► Fig.24: 1. Securing lip 2. Prefilter 3. Groove of
cleaner housing
Reassembly for high performance filter
Connect high performance filter. At this time, make sure
to twist high performance filter so that securing lip is
firmly locked into cleaner unit.
► Fig.25: 1. High performance filter 2. Securing lip
► Fig.26: 1. Securing lip
Connect capsule. Align O symbol on capsule with O
symbol on handle and then firmly twist capsule in direc-
tion of arrow until it is secured.
► Fig.27: 1. O Mark
► Fig.28: 1. Handle 2. Capsule