BACKWASH menu

This menu manages the filter backwash. When using the ProValve automated backwash valve it is possible to schedule
automatic backwashing (triggered by total filtration time).
For pools equipped with a manual 6 way valve, the system will guide the user through the backwash cycle. Backwash
duration can be programmed (in case of a variable speed pump with backwash at speed 4).
ControlPro has no means of verifying the water level in your pool. Performing a backwash with insufficient
water in the pool can lead to damage.
BACKWASH
MANU
Valve => BackWash
BackWash running
Valve => Rinse
Rinse running
Valve => Filtr.
BACKWASH TIME
2'15"
BACKWASH DELAY
250h
16
ControlPro
The backwash menu startup screen lets you start a backwash cycle or
enable automatic backwash.
Backwash with ProValve
When a ProValve is configured in setting menu these options are available:
OFF: disables automatic Backwash
MANU: starts a backwash cycle. Confirm with
backwash cycle.
Control pro will:
-
Stop filtration and dosing (10")
-
Activate the backwash Valve (10")
-
Restart the filtration (at speed 4 when using a VS pump) for the
programmed backwash time. The display will show 'backwash active'.
To halt backwash while running, press
-
Stop the pump (10")
-
Close the backwash valve (10"
-
Return to the normal Filtration mode and start the pump and the
dosing output.
AUTO: with this mode selected the pump will automatically start the
backwash cycle when the total number of filtration time reaches the
programmable 'backwash delay' time. Next day Backwash will begin
automatically at the start time for Prog 1 (in the filtration menu).
Backwash with a 6 way valve
The control pro system will guide you through the process. It will tell you
what position you need to position the 6 way valve. You will need to
confirm each step using
MANU: starts backwash procedure (you need to 2x
Pump stops –Put the 6 way valve on your pool filter in 'BACKWASH'
ENT
position. Then
Pump starts backwash for the programmed time (speed 4 on VS pumps).
It is possible to end the backwash using ESC.
Pump stops –Put 6 way valve in 'RINSE' position. Then
Pump runs for 8 sec (speed 4 with VS pumps)
Put 6 way valve back to 'FILTER' position. Then
The screen wil show 'OK'; Confirm with
This menu establishes the backwash duration. The backwash duration can
be adjusted in 15" intervals.
Backwash delay sets the time between automatic backwashes. Only
effective filtration time is taken into account.
Example: with 10hrs of filtration per day it will take 25 days before a
backwash takes place. After a backwash the time is reset. The main menu
has screen indicating the time until a next backwash. For systems not
having an automatic backwash, this setting serves as a reminder.
ENT
ESC
ENT
ENT
ENT
to start an automatic
ENT
)
ENT

Publicidad