- English -
Fitting the aerator motor
1. Place the aerator motor into the housing.
● Ensure that the air outlets are equipped with sealing rings.
● During fitting, there will be initial resistance from the two air outlets.
2. Screw the aerator motor in place.
Closing the housing
1. Place the top section of the housing onto the bottom
section and screw on.
● Ensure that the strain relief of the power
connection cable is correctly located in the recess
of the housing
Storage/Winterization
When the unit is in continuous operation it can remain in place at freezing temperatures.) Otherwise store the unit in- doors
in a dry room (room temperature).
Wearing parts
Membrane, air filter, and aerations stones are wear parts and are excluded from the warranty.
Disposal
Do not dispose of this unit with domestic waste! Disable the unit beforehand by cutting off the cables. Further
information about the recycling of this product can be obtained from your local municipal authority.
Troubleshooting
Issue
Unit does not run
Unit does not deliver air or
Insufficient delivered quantity
The unit is unusually loud
Questions, problems, missing parts?
Before returning to your retailer, call us at 1-866-627-3435, 8 a.m.-6 p.m., EST, Monday-Friday, or email
us at customercare@oase-livingwater.com. Or visit our website at www.oase-livingwater.com
Cause
No mains voltage
The aeration stones are soiled
The air filter is soiled
Air hose kinked or porous
Membrane is defective
Membrane is defective
Solution
Check mains voltage
Clean or replace the aeration stones
Clean or replace the air filter
Lay the air hose without kinks or replace
Replace both membranes
Replace both membranes
AquaOxy Set 240
7