TECshow CUBEX 360 Manual De Usuario página 5

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

4. Installation
The applicable temperature for the lighting is be-
tween -25°C to 45°C. Do not use the lighting under
or above the temperature.
The installation of the effect has to be built and
constructed in a way that it can hold 10 times the
weight for 1 hour without any harming deformation.
The installation must always be secured with a
secondary safety attachment, e.g. an appropriate
safety rope.Never stand directly below the device
when mounting, removing or servicing the fixture.
The operator has to make sure the safety relating
and machine technical installations are approved
by an expert before taking the device into opera-
tion for the first time.
These installations have to be approved by a
skilled person once a year.
Overhead mounting requires extensive experi-
ence, including amougst others calculating work-
ing load limits, installation material being used,
and periodic safety inspection of all installation
material and the device. If you lack these qualifi-
cations, do not attempt the installation yourself.
Improper installation can result in bodily injury.
Rigging
Mounting Bracket
Handing Bracket
Safety Rope
Rapid locking hook
P. 5
CUBEX 360
ENGLISH VERSION

Publicidad

Tabla de contenido
loading

Tabla de contenido