C6HTS /C6HTR Only – see figures D and F.
• The pre-set humidity operation is factory
set at approximately 75% Relative Humidity
(RH), but can be adjusted between 65% and
85% RH by control H.
• The over-run timer is factory set at 15
minutes but can be adjusted from 30
seconds to 30 minutes by control T.
• Turn the controls clockwise to increase RH or
time and anti-clockwise to decrease.
Using the fan
C4S / C4R Only
• Operate the fan using the on/off switch (not
supplied). Repeat to switch off.
C4PS / C4PR Only
• Operate the fan by pulling and releasing the
cord. Repeat to switch off.
C4TS /C4TR Only
• Operate the fan using an on/off switch (not
supplied). When the switch is turned off,
the fan continues to operate for the set time
delay. To adjust the over-run period, turn the
control "T" clockwise to increase and anti-
clockwise to decrease – see Figure D.
C4HTS /C4HTR Only.
• Automatic mode - The fan automatically
adjusts to slow changes in natural humidity
levels without operating the fan. If the
humidity levels increase at a rate slower
than 5% RH in 5 minutes, up to the pre-set
humidity level, the fan will not be triggered
by humidity. This is to prevent nuisance
triggering of the fan. If humidity levels
increase quicker than 5% RH in 5 minutes
the fan will operate. When relative humidity
drops the fan continues to operate for the
adjustable time delay.
• External operation - Use the external on/off
switch. When the fan is switched off, the fan
continues to operate for the adjustable time
delay then goes into automatic mode.
All Fans
Re-fit the front cover/baffle assembly by
hooking in the top first, and then swing the
cover down to clip into place. If surface mount
wiring, 'break out' the thin wall section in the
front cover prior to re-fitting (see figure E). The
miniature PVC trunking must then be sealed
against the front cover to prevent any water
ingress.
Cleaning
(recommended once a month)
1. Before cleaning, isolate the fan completely
from the mains supply.
2. Remove the front cover/baffle assembly by
depressing the latch on the underside of the
cover and pulling off the front cover / baffle
from the bottom.
3. To clean the front cover/baffle assembly,
either wipe it with a damp, lint free cloth or
wash it with warm soapy water. Thoroughly
dry the front cover and refit.
4. Do not immerse the fan in water or other
liquids to clean any other parts of the fan.
5. Do not use strong detergents, solvents or
chemical cleaners
6. Allow fan to dry thoroughly before use.
7. Apart from cleaning, no other maintenance is
required.
Disposal
This product should not be
disposed of with household waste.
Please recycle where facilities exist.
Check with your local authority for
recycling advice.
Guarantee
UK only
We, Redring Xpelair Group Limited, provide a
guarantee against faulty parts and manufacture
for a period of 2 years from the date of
purchase. In the unlikely event of a product
breakdown during the guarantee period the
product should be returned to the place of
purchase or to Redring Xpelair Group Limited.
Exclusions
• This guarantee does not cover compensation
for the loss of the product or consequential
loss of any kind.
• Damage or defects to the product arising
from incorrect installation or lack of
maintenance.
• Transportation costs.
This guarantee does not affect your
statutory rights