DIMMER CURVE
Use this menu item to set how the brightness of the spotlight increases or decreases in relation to the DMX value in the dimmer channel.
Press MODE repeatedly until "dCUr" (Dimmer Curve) is displayed and then press ENTER twice. Now set as desired using UP and DOWN.
Confirm your entry by pressing ENTER.
dC1 = Linear – light intensity increases linearly with the DMX value.
dC2 = Exponential – light intensity can be finely adjusted at lower DMX values and broadly adjusted at higher DMX values.
dC3 = Logarithmic – light intensity can be broadly adjusted at lower DMX values and finely adjusted at higher DMX values.
dC4 = S-curve – light intensity can be finely adjusted at lower and higher DMX values and broadly adjusted at medium DMX values.
DMX value
CONFIGURE DMX START ADDRESS
Press MODE repeatedly until the current DMX start address setting is displayed (Axxx) and then press ENTER. Now set as desired using UP
and DOWN (hold down key to quickly change values). Confirm your entry by pressing ENTER.
-
DMX MODE SETTING
Press MODE repeatedly until the current DMX mode setting is displayed (xCh) and then press ENTER. Now set as desired using UP and DOWN.
Confirm your entry by pressing ENTER. DMX tables with the channel assignments can be found in these instructions under DMX CONTROL.
/
SLAVE MODE
Press the MODE button repeatedly until "SLAV" appears on the display. Now connect the slave and the master units (same model) with
a DMX cable and enable one of the standalone modes on the master unit (individual colour temperature "C", colour temperature presets
"Pr"). The slave unit will now follow the master unit.
/
linear
exponential
DMX value
/
/
logarithmic
DMX value
/
/
S-curve
DMX value