Makita GC01 Manual De Instrucciones página 9

Pistola inalámbrica para aplicación de sellador
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

1
► 1. Holder
To remove the holder, follow the installation procedure
in reverse.
OPERATION
Using cartridge
Preparing cartridge for use
1.
Cut the tip of the cartridge nozzle so that the suit-
able amount of caulking material is fed.
1
► 1. Nozzle
2.
Make a hole on the protective film with the tip of
the nozzle.
1
► 1. Nozzle
3.
Attach the nozzle to the cartridge.
NOTICE:
Be sure to check the cartridge for
damage before installation. Using the damaged
cartridge may cause malfunction.
NOTICE:
When reusing the partially used car-
tridge, be sure to remove the solid caulking mate-
rial before the installation.
Installing cartridge to 300 ml (10 fl oz)
size holder
NOTICE:
Make sure that piston A is attached
to the rod. Do not use other type of piston for
cartridge.
1.
Pull the rod handle backward slowly until it stops.
► 1. Rod handle
2.
Insert the cartridge into the holder as shown in the
figure.
3.
Push the rod gently until the piston touches the
bottom of cartridge.
To remove the cartridge, follow the installation proce-
dure in reverse.
Installing cartridge to 600 ml (20 fl oz)
or 800 ml (29 fl oz) size holder
NOTICE:
Make sure that piston A (for 600 ml
(20 fl oz) holder) or piston D (for 800 ml (29 fl oz)
holder) is attached to the rod. Do not use other
type of piston for cartridge.
1.
Remove the holder cap from the holder, and then
pull the rod handle backward slowly until it stops.
9 ENGLISH
1

Publicidad

Tabla de contenido
loading

Tabla de contenido