Cebora CP41C Manual De Instrucciones página 5

Manual de instrucciones para antorcha plasma
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Porta ugello
Nozzle holder
Art. 1906
(5710670)
far apart and that the connections are firmly tightened.
4.4 REPLACING THE GRIP WITH TRIGGER -(FIG. 3)
Unscrew the screw A. Remove the grip F from the body
E by moving the grip back and forth, being very careful
not to tear the trigger wires when the two parts separate.
Disconnect the wires from the safety contacts G and H.
Disconnect the connection L. Unscrew the fitting I after
cutting the insulating tube K. Replace the grip and follow
all of the above steps in reverse order, being careful to
insulate the connection S.
Note - Insulate the fitting I by having the heat-shrink insu-
lating tube K adhere to it; this is done by heating it with
a small heat source (i.e., a cigarette lighter).
Ugello
Elettrodo
Nozzle
Electrode
Art. 1291
Art. 1878
(3110231)
(5710662)
Diffusore
Swirl ring
Art. 16418
(3160438)
Before mounting the grip, make sure that the cables are
far apart and that the connections are firmly tightened.
4.5 REPLACING THE CABLE -(FIG. 3).
Proceed as described in paragraphs 4.3, 4.4.
Remember to make and carefully insulate the connec-
tion R.
4.6 WARNINGS
Periodically make sure that the welding torch cable is
intact and has no cuts or excessive wear. Replace it
immediately if needed.
Fig. 2
5

Publicidad

Tabla de contenido
loading