How the water heater works:
• Water comes in through the cold water inlet.
The heater is designed for cold water supply
only. Do not supply with pre-heated water.
• The flow switch senses how much water is passing
through the unit. If it detects more than the preset
level, the unit's heating elements switch on. This is
shown by the neon light glowing.
• The water is heated instantly as it passes through the
copper heat exchanger tube.
The temperature of the water coming out of the unit
depends on:
• The voltage of the electrical supply,
• The temperature of the incoming water supply,
• The setting of the power selector,
• The flow rate,
• The power rating of the unit.
• Depending on the region of the country, the
temperature of the water supply can vary between
Model
Volts
Amps
US3
120-110
27
US7
240-220
15
US7
240-220
30
US9
208
18
US9
208
35
US9
240
20
US9
240
40
Table 4
Manual reset thermal cut-out
The unit has a thermal cut-out (Fig. 1) which is mounted
on the heat exchanger tube. This will switch off the
heater elements if the water temperature goes above
194 °F.
If the cut-out trips it will need to be reset manually inside
the unit. This cut-out will only operate in exceptional
6 720 800 537 (2011/09)
Element
High
Resistance
Setting
2x8 Ω
3,4-
3,0kW
1x16 Ω
-
2x16 Ω
7,2-
6,1kW
1x12 Ω
-
2x12 Ω
7,1kW
1x12 Ω
-
2x12 Ω
9,5kW
40 °F in winter to 70 °F in summer, with an average of
50 °F.
Fig. 3
A
Manual reset thermal cut out
The table below shows the rise in water temperature you
can expect from the unit:
Low
Temperature Rise (deg F) at Flow Rate
Setting
0,5
0,75
GPM
GPM
-
41F
28F
3,6-
NA
32F
3,05kW
-
NA
63F
3,5kW
NA
32F
-
NA
64F
4,75kW
NA
42F
-
NA
84F
circumstances (Fig. 3). Call your service person or Bosch
Water Heating if this happens frequently.