Troubleshooting - GreenWorks Commercial GBB 700 Manual Del Propietário

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

TROUBLESHOOTING

PROBLEM
Unit will not start.
Unit will not blow.
Cruise Control Lever
doesn't work.
Unit has blinking LED
lights.
POSSIBLE CAUSE
Battery is not secure.
Battery is not charged.
Defective power switch
Blocked tube.
The screw is loose.
One battery has been
depleted.
SOLUTION
Check to ensure the latches are tightly
secured into place on the back of the
blower and the battery. (Reference Page
13 of the instruction manual).
Charge the battery pack according to the
instructions included with your battery.
Return to place of purchase or return the unit
to a repair center.
Clear the blockage.
Tighten the screw with a phillips head
screwdriver.
Re-engage the trigger to activate the second
battery.
20

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido