Descargar Imprimir esta página

Becker BOM 650C Manual Del Usuario página 18

Ocultar thumbs Ver también para BOM 650C:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 31
Menu stage 5: The opening force limit
After approx. 2 seconds, the display flashes showing
the set value of the opening force limit. The force limit
setting can be increased for decreased via buttons
and
. After setting the value, press button
The display shows "6".
Menu stage 6: The closing force limit
After approx. 2 seconds, the display starts flashing,
and the set value for the closing force limit is
displayed.
The force limit setting can be increased or decreased
via buttons
and .
After setting the value, press button
in the display.
Finally, check the force settings, and, if necessary,
repeat the setting procedure.
The maximum force at the main closing edge must
not exceed 150 N!
Menu stage 7: Light phases
Keep button
pressed until "7" appears in the
display.
Menu
Light
Warning
value
phase
phase
0
60 s
-
1
120 s
-
2
240 s
-
3
0 s
-
4
0 s
3 s
5
0 s
0 s
6
0 s
3 s
7
90 s
3 s
8
90 s
3 s
9
0 s
10 s
When the advance warning time is set, the light and
24 V will be switched on before the drive starts
running.
The factory setting is 1.
Structural modifications and incorrect installation
which are not in accordance with these and our other
instructions can result in serious injuries, e.g.,
crushing of limbs. Therefore, structural modifications
may only be carried out with our prior approval and
strictly in accordance with our instructions,
Retain these installation, operating and maintenance instructions for the full duration of the operator's service life!
Menu stage 8: Door fitting
Press button
. "8" appears in the display.
Menu
Start
value
open
.
0
0
1
15
2
0
3
15
4
25
5
15
6
15
7
35
8
55
. "0" appears
9
These values correspond to the "soft" runs
measured in cm at the carriage.
Important note:
The factory setting of 4 must be adhered. The
softruns may only be alerted on the express per-
mission of the door manufacturer.
Press button
Menu stage 9: Operating modes
Falshing
Push button
. "9" is displayed.
function
-
Menu Operating mode
-
value
-
yes
0
Normal operation
-
(factory setting)
-
1
Normal operation with ventilation
yes
position
-
The ventilation position can be initiated via
yes
the signal 112 internal push button
yes
(accessory).
2
Partial opening of side sectional doors
Partial opening of approx. 1m can be
initiated via the signal 112 internal push
button (accessory).
particularly the information contained in these
Assembly and Operating Instructions.
Any further processing of the products which does
not comply with their intended use is not permitted.
Stop
Start
Stop
open
closed
closed
0
0
0
0
15
0
15
0
40
15
15
35
30
25
40
15
15
55
15
15
15
35
65
45
15
15
100
only soft run
. "0" appears in the display.
Warranty
6
Automatic Closing
Set open phase in menu stage A.
7
Automatic Closing
Break of open phase via light barrier.
8
Automatic Closing
Break of open phase via impulse
generator.
Operation mode Automatic Closing ( , ,
and ):
8
A light barrier has to be installed
Menu stage "A": Open phases of the door
Press button
. "A" is displayed. These phases can
only be set using the operation mode Automatic
Closing ( , , and ).
6 7
8
Menu
Open phase
value
(without warning time 10 seconds)
0
0 s
1
10 s
2
30 s
3
60 s
4
90 s
5
120 s
6
150 s
7
180 s
8
210 s
9
240 s
The end product manufacturer and fitter have to
ensure that all the relevant current statutory, official
and, in particular, EMC regulations are adhered to
during utilisation of our products, especially with
regard to end product manufacture, installation and
customer advice.
GB
6 7
13d
.

Publicidad

loading

Productos relacionados para Becker BOM 650C