G
B
RADIO CODE ERASING
1 - The boom arm must be completely closed.
2 - Turn DIP1 to ON position, the red LED DL1 starts blinking quickly
3 - Immediately, turn also DIP2 to ON position, the red LED DL1 starts blinking slowly.
Code erasing must be carried out within 10 seconds.
4 - Press the PROG button and hold it for 5 seconds, the total memory erasing will
be indicated by two flashes of the green LED DL9. The red LED DL1 will blink for
10 seconds and it will be possible to store new radio codes following the Point E
procedure described above.
5 - To end radio code storing either press PROG button or let 10 seconds pass. The LED
DL1 shall stop blinking.
6 - Turn DIP1 to OFF position.
7 - Turn DIP2 to OFF position.
FUNCTIONING OF CONTROL ACCESSORIES in NORMAL MODE (DIP6 OFF)
+
TIMER
ATTENTION: ONLY IMPULSIVE COMMANDS HAVE TO BE CONNECTED.
Make sure that any other type of command accessories (e.g. mass detectors)
used on the installation are set in the IMPULSIVE mode, otherwise, the gate
will be operated even without the protection of the safety devices.
OPEN1 BUTTON (COM - OPEN1)
The OPEN1 button performs the open command, regardless the position of the boom arm.
If the OPEN1 button is pressed during the closing, the boom arm stops and will reverse
the movement in opening.
In PARK MODE (DIP6 ON), if there is a vehicle at the entry (see scheme 4) and the
TLC contact is closed, the OPEN1 command opens the barrier. Otherwise, if the TLC
contact is open the OPEN1 command is disabled.
+
K BUTTON
LED
R=2K2
STOP
_
CLOSE
OPEN 1
LSC
LSO
LSSC
LSSO
RADIO CODE FULL MEMORY TEST
1 - The boom arm must be completely closed.
2 - Turn DIP1 to ON position, the red LED DL1 starts blinking quickly.
3 - Immediately, turn also DIP2 to ON position, the red LED DL1 starts blinking slowly. If
the green LED DL9 flashes six times, it means that the radio code memory is FULL
(maximum codes to be stored 60).
6 - Turn DIP1 to OFF position.
7 - Turn DIP2 to OFF position.
AERIAL
+
COAX
BUZZER
-
_
12 Vdc max 0,5A for ACCESSORY SUPPLY
+
_
12 Vdc max 0,5A for AUTOTEST EDGE
+
CLOCK FUNCTION
If you want the Clock Function must request PARK 230V with firmware 08
NOUP.
ATTENTION: A CLOCK CONNECTED TO PARK 230V with fw 05 or more
ACTIVATES THE OPENING MOVEMENT OF THE BARRIER WITHOUT HAVING THE
PROTECTION OF THE SAFETY DEVICES!
The Clock Function permits to keep the boom arm opened even if, for example, the
Automatic Closing is enabled (DIP3 ON) or somebody commands the barrier closing. It
is useful during rush hour, when traffic is heavy and the flow is low (e.g. entrance/exit
of employees, emergencies in residential areas or car parks) and it's necessary to keep
the boom arm opened.
24
STANDARD OPERATION
DIP 6 OFF
ENTRY
EDGE
NC
NO
COM
S
D-
D
+
MAGNETIC LOOP
TO EXIT
S
D-
D
3