CLOCK FUNCTION APPLICATION
It is necessary to request a PARK 230V control panel with firmware 08 NOUP.
It can be done by connecting a switch and/or a daily/weekly timer either in parallel to
the OPEN1 button or instead of the OPEN1 button. When the control board receives this
command, the boom arm will open and by keeping this contact closed for all the time of
the boom arm opening, the Clock Function is automatically activated.
In fact, once reached the open position, the barrier will remain opened and all of the
control board features are blocked. Only when the OPEN1 button is released, the control
board functions are re-activated and the boom arm will close immediately.
CLOSE BUTTON (COM - CLOSE)
The CLOSE button performs the close command, regardless the position of the boom
arm.
STEP BY STEP or AUTOMATIC COMMANDS (COM - K BUTT)
DIP5 - OFF => The K BUTT performs the cyclic command open-stop-close-stop-open
etc.
DIP5 - ON => The K BUTT performs:
- the open command, if pressed with the barrier completely closed
- the close command, if pressed with the barrier completely opened
- no effect, if pressed during the barrier opening
- the boom arm re-open, if pressed while the barrier is closing
OPERATING IN PARK MODE (DIP6 ON)
K BUTTON
STOP
CLOSE
+
OPEN 1
TO ENTER:
Provided there be a vehicle on the Entry magnetic loop (see scheme 4), opening can be
controlled by pressing OPEN1, K BUTT or RADIO switch (OPEN1 performs the boom arm
opening only if the TLC, connected to the Entry Magnetic Loop, contact is closed).
TO EXIT:
Provided there be a vehicle on the Exit magnetic loop (see scheme 4), opening can be
controlled by pressing OPEN2, K BUTT, RADIO switch. The OPEN2 can be connected to
the Exit magnetic loop.
If the DIP8 is turned ON, the OPEN2 will perform the barrier opening regardless the
presence of a vehicle at the Entry.
AERIAL
+
+
BUZZER
COAX
LED
R=2K2
-
12 Vdc max 0,5A for ACCESSORY SUPPLY
_
12 Vdc max 0,5A for AUTOTEST EDGE
+
REMOTE CONTROL
DIP4 - OFF => The REMOTE CONTROL performs the cyclic command open-stop-close-
stop-open etc.
DIP4 - ON => The REMOTE CONTROL performs:
- the open command, if pressed with the barrier completely closed
- the close command, if pressed with the barrier completely opened
- no effect, if pressed during the barrier opening
- the boom arm re-open, if pressed while the barrier is closing
AUTOMATIC CLOSING (DIP3 ON)
The Automatic Closing from the complete open position can be enabled turning ON the
DIP3. The maximum time that can be programmed is 5 minutes (see Point D).
_
+
If the DIP8 is turned OFF, the OPEN2 will perform the barrier opening if there is no vehicle
on the magnetic sensor connected to the TLC input (TLC contact opened).
In both the conditions, TO ENTER and TO EXIT, from the complete boom arm open
position:
If the Automatic Closing is enabled (DIP3 ON), the boom arm will close at the end of
the delay time programmed (see Point D).
If the Automatic Closing is disabled, the boom arm will remain open until a closing
command is pressed or until the vehicle passes in front of the photocells, giving an OK
CLOSE impulse to the control board (the OK CLOSE command can be connected to the
NO contact of the photocell receiver).
25
PARK OPERATION
DIP 6 ON
MAGNETIC LOOP
TO ENTRY
EDGE
NC
NO
COM
S
S
D-
D-
D+
D+
MAGNETIC LOOP
TO EXIT
G
B
4