11. ERROR MESSAGES

Power Peak® Quad EQ-BID 230V is equipped with special safety features to ensure
safe and reliable charging and discharging operation. As soon as a fault occurs, a cor-
responding message appears in the display and the piezo buzzer emits a shrill warning
tone. After eliminating the cause, the following error messages can be acknowledged by
pressing any button.
Operating Instructions
Charging or discharging started without connection
to battery, make connection
Battery connected with polarity reversed, check
connection
Break in charging/discharging current circuit, check
connection
Short-circuit in charging/discharging current circuit,
check connections
Battery/output voltage too high, check number of
cells
Battery/output voltage too low, check number of
cells
BID chip/key separated from charger during active ope-
ration, stop procedure, check connection to chip and
restart.
Voltage level of connected cell(s) has risen above
4.3 Volt.
Voltage level of connected cell(s) has fallen below
2.75 Volt for LiPo and LiIo or 2.0 Volt for LiFe.
Voltage sensor lead is not connected
21
45
# 30 8196