Technical Data; Powersine 200-12, 200-24 And 200-48 - tbs electronics Powersine PS200-12 Manual Del Propietário

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

damage or costs arising from improper use, use in an unsuitable environment, improper
installing of the inverter and inverter malfunctioning.
Since TBS cannot control the use and installation (according to local regulations) of their
products, the customer is always responsible for the actual use of these products. TBS
products are not designed for use as cricital components in life support devices or
systems, that can potentially harm humans and/or the environment. The customer is
always responsible when implementing TBS products in these kind of applications. TBS
does not accept any responsibility for any violation of patents or other rights of third
parties, resulting from the use of the TBS product. TBS keeps the right to change product
specifications without previous notice.
1)
Examples of improper use are :
- Too high input voltage applied
- Reverse connection of battery polarity
- Mechanical stressed enclosure or internals due to harsh handling and/or incorrect
packaging
- Backfeed via inverter output from external power source like public grid or
generator
- contact with any liquids or oxidation caused by condensation

5. TECHNICAL DATA

5.1

Powersine 200-12, 200-24 and 200-48

TECHNICAL DATA
1)
Output power
: @ Ta = 25C
Output voltage
Output frequency
Output waveform
Permissible cos  of load
Input voltage ( 3% tolerance) :
Maximum efficiency
No load power consumption at
nominal input voltage
[ASB]
PS200-12
Pnom
175W
P10minutes
210W
Psurge
400W
Nominal
12Vdc
Range
10.5
< 2.8W
[0.6W]
PS200-24
175W
220W
500W
230Vac  2% (115Vac  2% optional)
50Hz  0.05% (60Hz  0.05% optional)
True sinewave (THD < 5%
0.2 – 1 (up to Pnom)
24Vdc
2)
2)
– 16Vdc
21
– 31Vdc
90%
91%
< 3W
[0.8W]
15
PS200-48
175W
220W
500W
1)
@ Pnom)
48Vdc
2)
41
– 60Vdc
93%
< 4W
[1.2W]

Publicidad

Tabla de contenido
loading