OPERATION
ATTENTION: Do not continue to run machine
when battery meter needle is in the red zone,
battery damage will result.
11. While cleaning, view clear tube at rear of machine
for remaining cleaning solution. Each mark on
hose indicates 5 gal / 19 L.
12. When solution tank runs dry, turn off brush switch,
and continue to vacuum until all dirty water is
consumed. Then drain recovery tank
(See DRAINING TANKS).

STOPPING MACHINE

1. Turn off brush switch, and continue to vacuum
until all dirty water is consumed.
2. Release control grips.
3. Raise squeegee.
4. Turn off switches and remove key if equipped.
FOR SAFETY: Before leaving or servicing
machine, stop on level surface and turn off
machine.

EMERGENCY STOPPING (OPTION)

To stop machine in case of an emergency, hit the red
power kill button located at rear of control console.
The power kill button immediately stops all power to
machine (Figure 22).
To reset power kill button, shut off all switches and
turn kill button to the right. Resume to normal
operation.
14
FIG. 22
Home Find... Go To..

CIRCUIT BREAKERS

The machine is equipped with (4) circuit breakers to
protect machine from damage.
If circuit breakers should trip, the breakers will not
reset immediately upon tripping. Determine reason
why breaker tripped, allow motor to cool and reset.
Brush motor circuit breakers will trip due to excessive
overload on pad. Reduce pad pressure or replace pad
if breaker should trip.
The main and drive/vacuum circuit breakers are
located at the rear of machine. The brush motor circuit
breakers are located near the charging plug
(Figure 23).
-- 10A Main Circuit Breaker
-- 35A Drive Motor/Vacuum Circuit Breaker
-- 30A Brush Motor Circuit Breaker (2)
-- 10A FaST System (Option)
FIG. 23
FaST Model
Brush
Motor
Circuit
Breakers