Starting And Stopping; Before Starting; Starting; Stopping - Husqvarna DMS 240 Manual De Instrucciones

Ocultar thumbs Ver también para DMS 240:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Before starting

WARNING! Note the following before
!

starting:

The machine should be connected to an
earthed outlet socket.
Check that the mains voltage corresponds
with that stated on the rating plate on the
machine. Keep people and animals well
away from the working area.
WARNING! Before drilling, check that all
!
locking screws are tightened well.
Serious accidents can occur if the concrete
core remains in the drill when backing out
the drill motor/drill from the floor, wall or
ceiling.
Prevent unintentional starting. Ensure the switch is in
the OFF-position before connecting to power source
and/or battery pack, picking up or carrying the tool.
Carrying power tools with your finger on the switch or
energising power tools that have the switch on invites
accidents.
Remove any adjusting key or wrench before turning
the power tool on. A wrench or a key left attached to a
rotating part of the power tool may result in personal injury.
Make sure that:
The switch is undamaged. If not, the switch must be
replaced by an authorised repairman.
The machine and its equipment are correctly installed:
- The drill is secured properly.
- The stand is firmly attached.
- Secure the machine on the stand using a suitable method.
Wear personal protective equipment. See instructions
under the "Personal protective equipment" heading.
Water cooling is undamaged and connected to the
machine.
Residual-current device
Make sure the ground fault circuit interrupter is switched on.
The LED indicates that the ground fault circuit interrupter is on
and that the machine can be switched on. If the LED is not
on, push the RESET button (green).
Check the ground fault circuit interrupter. See instructions
under the heading Checking, maintaining and servicing the
machine's safety equipment.

STARTING AND STOPPING

Drilling in the ceiling
WARNING! The vacuum plate must never be
!
used for ceiling drilling.
Use a water collector to avoid water
penetrating into the machine. The machine
must be covered with plastic or the like in
order to prevent water penetrating into the
machine, but do not cover the air intakes
and air outlets.
WARNING! Check that no one on the floor
!
below can be injured by falling concrete
cores.
Starting
Turn on the water cooling.
Press in the switch fully.
Allow the machine to come up to full speed before
contacting workpiece.
Start to feed the drill bit with the help of the feed handle.
Use very light pressure for the first few millimeters to keep
the bit from wandering. Then proceed normally. It's not
necessary to use excessive force. This will only slow
drilling and overload the motor.
Use especially light pressure when you encounter steel
reinforcing rods. High pressure against reinforcing rods
will trip the circuit breaker. If the circuit breaker trips,
remove the bt from contact with the workpiece before
resetting.

Stopping

WARNING! The drill bit continues to rotate
!
for a while after the motor has been switched
off. Do not stop the drill bit with your hands.
Personal injuries can occur.
Shut down the machine by pressing the power switch.
Cooling
Run the machine unloaded for a minute or two to cool the
motor.
This will also blow dust and dirt out of the motor, ensuring
longer life for the machine.
– 13
English

Publicidad

Tabla de contenido
loading

Tabla de contenido