5.2.5- The door will open and close automatically to map the open
and close sensitivity force requirements.
5.2.6- It displays "
symbol " - " it means that the setting position wasn't saved. See
the possible solution in Chapter 6.2 "Troubleshooting".
5.3 Remote control – full capacity & erase stored codes
5.3.1- When the unit has stored 20 codes, it flashes " F " (memory
full), you should not store more codes.
If you need to store more than 20 codes, you will need to use an
external receiver.
5.3.2- Press and hold button CODE more than 8 seconds, it displays
" ". After the 8 seconds it flashes " C ", all the codes were cancelled.
5.4 Adding or changing remote controls and/or wireless push
buttons
5.4.1- Press button CODE, it displays "
5.4.2- Press two times the button desired on the remote control or on
the wireless push button, " " flashes.
5.4.3- Repeat the previous steps to code a maximum of 20 different
remote controls and/or wireless push buttons.
5.5 Force adjustments (if necessary)
5.5.1-
Press and hold button SET pressed, until it displays " 3 ", and
as soon as you release the button, it shows the number relative to
the current level of Force (" 1 " or " 2 "). The default setting is " 2 ".
5.5.2- Now that it is showing the current situation, press button UP to
increase the force one value, or press button DOWN to decrease
one value. The maximum value is 2 and minimum is 1 .
LIKE IT
I I
" to show setting is complete.
" "
If you see the
".
" "
EN
46