Explanation of functions/terms used
Wind protection function
Retracts and blocks extension of the awning if the wind threshold value is ex ceeded
(preset delay: 15 min.).
Sun protection function
Extends the awning if the sun threshold value is exceeded (preset delay: 5 min.).
Retracts the awning if the sun threshold value is not achieved (preset delay: 15
min.).
Rain protection function (only i-R Marki WSRF)
Retracts the awning and prevents automatic extension.
Frost protection function (only i-R Marki WSRF)
Prevents extension of the awning at temperatures below +4 °C.
Twilight function
Retracts the awning during twilight hours (mornings and evenings).
TEST MODE
It is possible to test the sensor in this mode. In the TEST MODE the times of the
sun protection and wind protection functions are reduced from minutes to seconds.
A possible wind alarm is reset.
Data transfer
The sensor transfers the current wind and sun values to the receiver via radio signals
at approx. one minute intervals.
Awning indicates:
Wind alarm ➞ Manual extension is stopped after 2 sec. and the awning re tracts.
Sensor loss ➞ Manual extension is stopped after 4 sec. and the awning retracts.
25
GB