Filter Assembly; Troubleshooting - Astralpool 11619 Manual De Instrucciones Y Funcionamiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 1

6.3 Filter assembly

Before assembling the filter, carefully clean and inspect tank and O-ring groove, either at the upper as all
the lower part of the filter, checking that there are no fissures or damages. If necessary, lubricate O-ring
with silicone oil.
• Put the O-ring in the lower tank shell.
• Carefully push the upper tank shell over the lower one to compress the O-ring, checking that the
O-ring has not moved.
• Insert the clamp and alternately tighten the nuts little by little, checking all time that the upper
tank shell is centred and clamp is tightening correctly.
6.4 Grid assembly cleaning procedure
At least once a year, it is recommended to completely dismantle the filter to remove algae, body oils and
calcium or magnesium deposits from the grids. Cleaning best before ending season.
• Run a complete filter "Backwash" according to section 6.1.
• Disassemble filter according to section 6.2.
• Pull top mounted manifold to remove grid assembly.
• Unscrew the manifold nut and remove grids and internal air bleed assembly. Pay attention to
grids position at supporting grid as one of the 8 grids in smaller (see Fig. 6).
• Clean air bleed assembly and grids using a soft brush and industrial detergent.
• If necessary, leave grids to soak for several hours. Put every grid into a separate tank and soak
with a commercial filter cleaner. Follow cleaner manufacturer's instructions carefully.
• Rinse using plenty of water at low pressure.
• To assemble grids easily, put manifold inverted on the ground. Softly insert grids in the manifold
grooves, considering the position of the smaller plate.
• Place the supporting grid over the 8grids. Introduce the tie rod turn over the assembly, put the
washer and thread nut softly. Check all grids are placed correctly. Tighten nut slowly. Do not
overtighten.
• Put the air bleed assembly.
• Introduce the grid assembly into the filter by pushing the manifold softly in order to introduce it
into the pipe.
• Assemble filter according to section 6.3.
When
very cold weather conditions, after "Grid assembly cleaning procedure" drain all water from
installation and cover filter.

7. TROUBLESHOOTING

PROBLEM
Low filtration flow
Pressure increases quicky
Bubbles in outlets
PROBABLE CAUSE
Dirty filter
Dirty pump filter
Clogged pipes
Dirty filter
Algaes into pool
Wrong D.E. amount
Low level of pool water
Inlet valves partially closed
Dirty pump filter
SOLUTION
Operate "BACKWASH"
Clean prefilter
Check valves and inlets/outlets
Operate "BACKWASH"
Chemical treatment
Backwash and precoat with
exact quantity
Fill up pool
Open valves
Clean prefilter

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

116201162111622

Tabla de contenido