Conductivity probe
1
yellow
2
transparent
Cover
1
5
&
Chlorine probe detector
FL2
(rotameter)
3
black
5
brown
6
blue
Flow switch
FL1
2
5
&
pH-Minus deposit
level
4
5
TANK
&
Temperature probe
1
red
2
yellow
3
black
AUX 1
Dosing pump flocculation
pH
APF
pH dosing pump
1
2
&
B.1
C.1
C.1 The 7 available relays
can be hooked up to various
predefined external devices
being controlled by the unit.
DA-GEN
Dryden Aqua Generator
SERVICE MANUAL
A) ELECTRICAL CONNECTIONS
110-230 V
1
max. 3.15 A
2
1 2 3 4 5 6
1
2
3
4
5
6
7
8
1 2 3
AUX 2
Besgo backwash
®
valve
5
&
6
B) SERVICE MENU
B.2
C) RELAY CONFIGURATION
C.2
C.2 The predefined functions are:*
pH: Acid pH-pump.
Filter: Filtration pump.
Light: Pool lights.
AUX 1: APF
AUX 2: Besgo Valve
AUX 3: ACO
AUX 4: Heat pump or other heating device.
* Recommended relay settings.
CONNECT ALL THE SENSORS CAREFULLY, A
BAD CONNECTION MAY CAUSE IRREPARABLE
DAMAGE TO THE DEVICE
DRY CONTACT
7 8 9
10 11 12 13 14
Free chlorine
4
3
red
black
N
L
A1 A2
14
11
12
FILTER PUMP
LIGHT
Filtration control
Lighting control
9
&
10
7
8
&
B.3
®
®
10
PASSWORT MENU INSTALLATEUR:
ASK YOUR SUPPLIER OR POOL
BUILDER
1 2 3 4
Variable speed pump
1
1
3
2
3
Device control SLAVE
4
1
1
1
1
2
2
2
Connection remote display*
3
3
3
4
4
Connection WIFI module
4
1
3
*In case of connecting 2
redoX
pH
display´s on the device,
remember not to connect
the remote display in this
communication channel. Use
the "Extern" channel instead.
ACO
®
AUX 4
11
&
12
Heating control
13
&
14
B.4
Accessing the Service Menu:
B.1: Main screen (according to model)
B.2: Select System Settings
B.3: Select Service Menu
B.4: Enter password
Note: "NO" will deactivate the predefined
parameters and leave the relay available.
2
slow
medium
4
fast
common
2
brown
blue
red
2
yellow
4
green
black