2. Place the tool's Angle Base
on the first working surface.
Make sure that the tool remains
stationary and press the Down
Arrow Button for 1 second
to enter the relative angle
measurement mode. The current
angle will be set to 0.0°; the LCD
screen will display
(FIG. 14).
3. Place the tool's Angle Base
on the second working surface. The relative angle between the
first working surface and the second working surface will be
displayed.
4. Press the Down Arrow Button for 1 second again to release from
the mode; the icon
NOTE: The tool will beep at the new reference value 0°, 45° and
90° in the same way as the absolute value 0°, 45° and 90° shown in
the Absolute Angle Measurement.
NOTE: Arrows
and 90° in the same way as the absolute value 0° and 90° shown in
the Absolute Angle Measurement.
NOTE: When the tool inclines more than approximately 45° forward
or backward, the LCD screen will indicate "--.-°" (FIG. 15).
Fig. 15
will disappear.
will also display at the new reference value 0°
Forward
Backward
Fig. 14
25