Instructions for use (rev 05/18)
When the desired changes of program have been made, press "SAVE" key to save the complete
program.
After validation, the "Working interface" displayed on the screen.
6.4.2. Programming instructions
C: Temperature in degrees Celsius (°C)
T: Time in minutes (min)
- Temperature 1: used as the temperature start value (usually set to 0)
- Time 1: total duration of first stage (0 to 9999 minutes).
- Temperature 2: final temperature of first stage and start temperature of second stage.
Temperature values from C1 to C2 define the increase rate, the recommended value must be
less than 10 °C/min.
- Time 2: total duration of second stage (0 to 9999 minutes).
- Temperature 3: final temperature of second stage and start temperature of third stage. If C3 is
less than C2 (temperature decrease), the recommended value must be less than 30 °C/min.
- Time 3: total duration of third stage (0 to 9999 minutes).
- Temperature 3: final temperature of third stage and start temperature of fourth stage. If
necessary, the parameters are programmed as for the previous steps.
Last time "-121" indicates the end of program, temperature controller works according to the
temperature/time parameters setting. When the program detects a "-121", the control program
execute "STOP" command to return to the first program segment. STOP command is activated
with return to the previously selected program. "-121" also indicates correct cycle sequence.