Instructions for use (rev 05/18)
8.1. Heating element replacement
Observe these conditions for replacing heating elements:
- preferably, be at room temperature (+15°C / +25°C), the heating elements are very sensitive to
temperature;
- handle them carefully;
- keep all elements of heating elements: heating elements and cushioning foam pad protecting.
Steps to heating element replacement:
1. Open the furnace upper cover
(unscrew)
3. Repeat step 2 for all the heating elements
to replace
UGIN DENTAIRE
2. Unscrew the electrical contacts of heating
elements with a wrench (supplied as an
accessory)
4. Unscrew the support elements of heating
element with a wrench (supplied as an
accessory)
5. Remove carefully the
cushioning foam pad
protecting heating elements.
Lift carefully the heating
element with the elements
protecting.
e.ON SINTER
43