Caution ............................................................................................................................................
Before Installation ...........................................................................................................................
Tools You Will Need ........................................................................................................................
Installation Procedure......................................................................................................................
Calibrating the Valve .......................................................................................................................
Troubleshooting ..............................................................................................................................
Rough-In .........................................................................................................................................
®
TOTO's
mission is to provide the world with healthy, hygienic and more comfortable lifestyles. We
design every product with the balance of form and function as a guiding principle. Congratulations
on your choice.
RISK OF SCALDING: THIS VALVE MUST BE CALIBRATED BY THE INSTALLER. SEE VALVE CALIBRA-
TION PROCEDURE. Once calibrated, this valve has a limiter to prevent the temperature from exceeding
120º F (49º C).
This valve was calibrated at the factory at the following conditions:
Hot: 140º F (60º C) at 14.5 psi (0.1 Mpa)
Cold: 60º F (15º C) at 14.5 psi (0.1 Mpa)
Operating condition:
Minimum Pressure .................7 psi
Maximum Pressure ................108 psi
If the water pressure exceeds 108 psi, use a pressure reducing valve to reduce the pressure down to a safe
level.
shorten the life of valve or damage the valve and could result in leaks.
Do not reverse the hot and cold water inlets.
Do not use steam for hot water supply.
Do not disassemble the thermo unit.
TABLE OF CONTENTS
®
! ........................................................................................................
THANKS FOR CHOOSING TOTO
CAUTION
!
2
º F (85º C). Using the valve above this temperature will
!
®
2
2
3
3
4
5
6
7