9. Spare parts, parts subject to wear and special
accessories
Name
Sampling sensor for part-load analyses
Sampling sensor, 600 mm long
Gas sampling hose,
8 m Viton 5 x 1.5
Test jack for leakage test
- O-ring for test jack
PVC hoses,
set of three, 0.7 m PVC 5 x 1.5
Silicone hose for 2-stroke-engine analyses 1 687 001 283
Hose,
0.3 m Viton 6 x 3
Filter (e.g. GF1/2/3)
Activated charcoal filter
sensor Bosch A7-11.5 or
O
2
CLASS R-17A BOS
Interconnecting cable, ETT 8.70 to
MOT 151/240/250/251
Interconnecting cable, ETT 8.70 to
FSA 560/600 or Emission System Analysis 1 684 465 233
10.
Order number
Analysis
1 680 790 036
CO measurement range 0.000 to 10.00 % CO 0.001 % vol.
1 680 790 016
HC measurement range 0 to 9999 ppm HC
1 680 706 013
CO
2
1 684 485 280
1 680 210 089
O
measurement range
2
1 687 001 355
Lambda
1 680 706 017
Mains power supply
1 687 432 005
1 687 432 014
Power input
Permissible ambient temperature
Permissible relative humidity
1 687 224 727
Air pressure
Normal position
Height of installation location:
1 684 465 264
(length of outlet hoses):
Warming-up time
System equalisation
Measurement gas flow
Display delay
Weight
10.1 Temperature limits
- Storing temperature
- Continuous load for viton hose
and sampling sensor
- Peak load for
sampling sensor
10.2 Sound power level to DIN 45 635
- Sound power level L
- Emission value L
11. Guarantee
If any modifications are made to or non-genuine accessories
used with IA4 products, all rights under guarantee shall be
invalidated.
Technical data
Measurement range
by vol.
by vol.
measurement range 0.00 to 18.00 % CO
by vol.
0.00 to 22.00 % O
by vol.
0.500 - 1.800
(at modus: measurement)
63,5 dB(A)
WA
at workplace: 47 dB(A)
pA
Resolution
1 ppm by vol.
0.01 % by vol.
2
0.01 % by vol.
2
0.001
100 V, 120 V, 230 V, 240 V
selectable with bridges,
50 or 60 Hz
(setting only by a Bosch
service agency)
110 VA
+2 °C to +45 °C
5 % to 90 %, without dew
700hPa to 1100hPa
horizontal ±5°
min. 250 mm from floor
min. 300 mm
3 minutes
30 seconds, automatic, if
required
4 l/min (min 2 l/min, max 6l/min)
< 15 seconds for 95 %
measurement accuracy
10 kg
-20 °c to +65 °C
max. 200 °C
max. 250 °C for < 3 min
29