Vaillant sensoHOME VRT 380f Manual De Uso E Instalación página 14

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

2 Product description
MENU → SETTINGS → Installer level → Installation configuration
→ Max. target flow temperat-
ure:°C
→ Set-back mode:
The behaviour can be adjusted separately for each heating circuit.
→ Room temp. mod.:
12
Enter the upper limit for the target flow temperature. The
control compares the set value with the calculated target
flow temperature, and regulates to the smaller of these val-
ues.
→ Eco
→ Normal
→ Inactive
→ Active
→ Expan-
ded
Operating and installation instructions sensoHOME 0020298974_00
The heating function is switched off and the
frost protection function is activated.
At outdoor temperatures that are below
4 °C for longer than four hours, the control
switches the heat generator on and regulates
to the Set-back temperature: °C. At an
outdoor temperature above 4 °C, the control
switches the heat generator off. The monit-
oring of the outdoor temperature remains
active.
Heating circuit behaviour outside of the time
periods. Prerequisite:
– Time-contr. is activated in the Heating →
Mode: function.
– Active or Inactive is activated in the
Room temp. mod.: function.
If Expanded is activated in the Room temp.
mod.:, the control regulates to the target
room temperature 5 °C independently of the
outdoor temperature.
The heating function is switched on. The con-
trol regulates to the Set-back temperature:
°C.
Prerequisite:
– Time-contr. is activated in the Heating →
Mode: function.
Adjusting the flow temperature based on the
current room temperature.
Adjusting the flow temperature based on the
current room temperature. The control also
activates/deactivates the zone.
– The zone is deactivated: Current room
temperature + 2/16 K > set room temper-
ature
– Zone is activated: Current room temperat-
ure < set room temperature - 3/16 K

Hide quick links:

Publicidad

Tabla de contenido
loading

Tabla de contenido