Condition: The heat generator does not have an
option to connect it directly and/or is installed in the
wet environment.
▶
Remove the flap on the radio receiver
unit in accordance with the figure.
▶
Remove the existing cable for the direct
connection.
▶
Connect the eBUS cable, which is to
be provided on-site, in accordance with
the figure.
▶
Seal the flap on the radio receiver unit.
▶
Install the wall-mounting screws out-
side of the wet environment in accord-
ance with the figure.
▶
Fit the radio receiver unit onto the wall-
mounting screws.
0020298974_00 sensoHOME Operating and installation instructions
-- Electrical installation, set-up 3
6 0
m m
2,6 mm
▶
When opening the electronics box in
the heat generator, proceed as de-
scribed in the installation instructions
for the heat generator.
▶
Use an extension cable to connect
the radio receiver unit to the eBUS
interface in the heat generator's elec-
tronics box in accordance with the fig-
ure. The LED lights up green after 20
seconds at the latest.
3.5 Installing the control
1. Read the operating concept and the
operating example described in the
operating instructions for the control.
2. Stand next to the radio receiver unit.
B
A
3. Open the control's battery compart-
ment as shown in the figure.
4. Insert the batteries, making sure that
the poles are the right way round.
◁
The installation assistant starts.
5. Close the battery compartment.
6. Select the language.
7. Set the date.
X24
X100
15