Product Data In Accordance With Eu Ordinance No. 811/2013, 812/2013; Technical Data; Radio Receiver Unit - Vaillant sensoHOME VRT 380f Manual De Uso E Instalación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

6 Information about the product
6.8 Product data in accordance
with EU Ordinance no.
811/2013, 812/2013
On units with integrated weather-com-
pensated controls, including a room ther-
mostat function that can be activated, the
seasonal room-heating efficiency always
includes the correction factor for control
technology class VI. The seasonal room-
heating efficiency may deviate if this func-
tion is deactivated.
Temperature control class
Contribution to the seasonal
room-heating energy effi-
ciency ɳs

6.9 Technical data

6.9.1 Control
Battery type
Rated surge voltage
Frequency band
Max. transmission power
Range outdoors
Range indoors
Pollution degree
IP rating
Protection class
Temperature for the ball
pressure test
Maximum permitted envir-
onmental temperature
Current room air hum.
Mode of operation
Height
Width
Depth

6.9.2 Radio receiver unit

Rated voltage
Rated current
Rated surge voltage
Frequency band
20
Max. transmission power
Range outdoors
Range indoors
Pollution degree
IP rating
Protection class
Temperature for the ball
pressure test
Maximum permitted envir-
onmental temperature
Rel. room humidity
VI
Supply line cross-section
Height
4.0 %
Width
Depth
LR06
330 V
868.0
... 868.6 MHz
< 25 mW
≤ 100 m
≤ 25 m
2
IP 20
III
75 ℃
0 ... 60 ℃
35 ... 95 %
Type 1
109 mm
175 mm
27 mm
9 to 24 V
< 50 mA
330 V
868.0
... 868.6 MHz
Operating and installation instructions sensoHOME 0020298974_00
< 25 mW
≤ 100 m
≤ 25 m
2
IP 21
III
75 ℃
0 ... 60 ℃
35 ... 90 %
0.75
... 1.5 mm²
115.0 mm
142.5 mm
26.0 mm