Produktgruppen 522, 592
28 von 30
Danger!
Risk of injury during installation:
Risk of electric shock. Before starting any service work, the machine must be disconnected from the power supply.
Installation can only be carried out with the washing machine or tumble dryer not installed. For deinstallation, see the appropriate
operating instructions.
Risk of crushing. Wear slip-proof working gloves and safety shoes.
Risk of crushing. When carrying out work, ensure that parts of the body, especially the hands and feet, are not positioned under or
between machines.
Risk of accident. Ensure that children or pets cannot access the work area while installation work is being carried out.
Risk of injury, particularly to the back. The relation of the weight of the machine to the physical strength of the technician must be
taken into account. For machine weight details, see the appropriate operating instructions.
Risk of toppling over. Risk of injury due to incorrect installation.
Always bolt the machine to the stand.
With a single-machine installation, secure the stand to the floor with the fastening accessory, mat. no. 01497252, supplied with the
kit.
Use the floor fastening to secure all four stand feet.
Note
The stand may only be used with the following Miele models:
UO 8250 / UG 8250 = PT 8251, PT 8251 COP, PT 8253, PT 8255, PT 8257
UO 8330 / UG 8330 = PT 8331, PT 8331 COP, PT 8333, PT 8335, PT 8337
Note
Tools required:
Bubble level for stand leveling
Drill
12mm drill bit
13mm wrench for M8 nut
2 10mm wrenches for M6 nut
T-20 screwdriver
Note
Installation kit no. 07761970 or 07762000 contains the following:
UO 8250 or UO 8330 stand
Floor fastening accessory pack containing 4 clamps, 8 galvanized B6.4 washers, 4 M6 x 20 bolts, 4 M6 nuts, 4 S12 rawl plugs,
4 8.4 washers, 4 8 x 65 hex woodscrews, 20 spacers, 8 38mm washers
Information sheet with these instructions and accessing card. These installation instructions are called, Installation Instructions -
Stand UO 8250/UO 8330, UG 8250/UG 8330.
Note
Installation kit no. 07761950 or 07761990 contains the following:
UO 8250 or UO 8330 stand, 1 front panel, 2 side panels, 8 4.8 x 9.5 raised-head screws and 4 rubber bumpers (for UG 8250
stand)
Floor fastening accessory pack containing 4 clamps, 8 galvanized B6.4 washers, 4 M6 x 20 bolts, 4 M6 nuts, 4 S12 rawl plugs,
4 8.4 washers, 4 8 x 65 hex woodscrews, 20 spacer plates, 8 38mm washers
Information sheet with these instructions and accessing card. These installation instructions are called, Installation Instructions -
Stand UO 8250/UO 8330, UG 8250/UG 8330.
List of illustrations:
Fig. 1, Stand height
Fig. 2, Floor fastening holes
Fig. 3, Floor fastening hole dimensions
Fig. 4, Floor fastening
Fig. 5, Clamp installation
Fig. 6, UG 8250/UG 8330 stand
28.09.2010