Machine Maintenance; Daily Maintenance - Nobles STRIVE Manual Del Operador

Limpiador de alfombras de tecnologíadual
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

FOR SAFETY: When servicing machine, wear
protective gloves and eye protection when
handling batteries and battery cables. Avoid
contact with battery acid.
4. Connect the charger's AC power supply cord to a
properly grounded receptacle.
5. Connect the charger's DC cord to the machine's
battery receptacle located under the recovery tank
(Figure 23). Rest the recovery tank on the support
stand to promote ventilation during charging.
6. The charger will automatically begin charging and
shut off when fully charged.
NOTE: The machine will not operate once the battery
charger is connected.
ATTENTION: Do not disconnect the charger's DC
cord from the machine's receptacle when the
charger is operating. Arcing may result. If the
charger must be interrupted during charging,
disconnect the AC power supply cord first.
WARNING: Fire Or Explosion Hazard.
Batteries Emit Hydrogen Gas. Keep Sparks And
Open Flame Away. Keep Battery Compartment
Open When Charging.
7. After charging, check the electrolyte level (A)
again. The level should be approximately 1 cm
(3/8") from the bottom of the fill--port (B) (Figure
24). Add distilled water if needed. DO NOT
OVERFILL.
B
A
Nobles Strive (04- -07)
FIG. 23
FIG. 24
Home
Find... Go To..

MACHINE MAINTENANCE

To keep the machine in good working condition, simply
follow the daily, weekly and monthly maintenance
procedures.
FOR SAFETY: Before leaving or servicing
machine, stop on level surface and turn off
machine.
WARNING: Electrical Hazard. Disconnect
Battery Cables Before Servicing Machine.
ATTENTION: Contact an Authorized Service
Center for machine repairs. Machine repairs
performed by other than an authorized person will
void your warranty.

DAILY MAINTENANCE

(After Every Use)
1. Drain and rinse out the recovery tank (Figure 25).
FIG. 25
2. Rinse off the float shut-off screen located in
recovery tank (Figure 26).
FIG. 26
3. Drain and rinse out the solution tank.
OPERATION
17

Publicidad

Tabla de contenido
loading

Tabla de contenido