Descargar Imprimir esta página

Novoferm TAD MS Instrucciones De Montaje página 25

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 38
Programming Overview
3-9
Menu-
No.
Entry
Selection
point
4
Status relay X5
0*
Door closed signal
1
Door open signal / loading lamp
2
2 minutes garage light
45
3
5 minutes garage light
4
Hand transmitter on / off
5
Wipe impulse ELTACO
6
Signal for automatic return
Status relay X6
0
Door closed signal
1*
Door open signal / loading lamp
2
46
Red traffic light without early warning phase
3
Red traffic light with 3 seconds early warning phase
4
Red traffic light with 10 seconds early warning phase
Spring breakage detection
Display spring balance (press 5 sec.)
47
0*
off
1 - 99
Input spring force
Opening force limit
0*
off
48
1 - 98
Input cut-off force
99
Carry out weight measuring run with test weight
Motor starting time
Without limitation
Gear motor 5.24
Gear motor
49
Gear motor
Gear motor
Gear motor 9,24 WS
Gear motor
- -
Exit menu
5
Key switch function (J7)
0*
no function
1
Block control panel
2
Block external control elements
50
3
Block control panel and external control elements
4
Activating the control elements for 10 secs.
Function of external impulse generators
Three-button-control
51
0*
1
Open-Stop-Close function (J1.4 full-opening)
52
001-256
Entering the control address
Module door control
53
0*
off
1, 2, 3
Control profiles see module door control
Extension control unit
54
off
0*
1, 2, 3
Control profiles see extension control unit
- -
Exit menu
Menu
30-
25min / 35%
5.24 WS
25min / 30%
6.65 DU
25min / 60%
9.15, 9.20, 9,24
25min / 20%
10min / 35%
14.15
25min / 60%
Item
1x
Menu-
No.
Entry
Selection
point
6
60
Programming the start button on the transmitter
62
Programming the light button on the transmitter
Deleting radio codes (press for 5 sec.)
63
- -
Exit menu
9
Selecting the door's service intervals
0*
no service interval
1
1000 cycles
2
4000 cycles
3
8000 cycles
4
12000 cycles
5
16000 cycles
90
6
20000 cycles
7
25000 cycles
8
30000 cycles
9
35000 cycles
10
40000 cycles
11
45000 cycles
12
50000 cycles
Issue of cycles counter door
91
91
Selecting the dock leveller's service intervals
0
500 cycles
1
1000 cycles
2
1500 cycles
3
2000 cycles
4
2500 cycles
5
3000 cycles
6
3500 cycles
92
0*
7
4000 cycles
8
4500 cycles
1
9*
5000 cycles
2
10
5500 cycles
3
11
6000 cycles
4
93
Issue of cycles counter dock leveller
5
Selecting the shelter's service intervals
6
0
500 cycles
1
1000 cycles
2
1500 cycles
3
2000 cycles
4
2500 cycles
5
3000 cycles
6
3500 cycles
94
7
4000 cycles
8
4500 cycles
9*
5000 cycles
10
5500 cycles
11
6000 cycles
95
Issue of cycles counter shelter
96
Issue of operating hours counter
97
Issue of error memory
98
Issue of
99
Resetting of factory setting (press for 5 sec.)
- -
Exit menu
Enter
-
-
cycles
-
cycles
-
-
cycles
-
-
hours
-
-
hours error code
-
-
-
software version serial no.
date
* Factory settings
GB
Exit
-
-
-

Publicidad

loading

Este manual también es adecuado para:

Had ms 400vHad ms 230v