Maintenance And Cleaning; Accessories - IKA RV 10 control Instrucciones De Manejo

Ocultar thumbs Ver también para RV 10 control:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

The device is maintenance-free. It is subject only to the natural wear and
tear of components and their statistical failure rate.
The seal on the glass condenser should be checked at regular intervals
and replaced if necessary.
For cleaning disconnect the main plug.
To clean the device use only water with a detergent that contains tensi-
des, or use isopropylalcohol for stubborn soiling.
Spare parts order
When ordering spare parts, please give:
- Machine type
- Manufacturing number, see type plate
- Item and designation of the spare part,
see www.ika.com, spare parts diagram and spare parts list

Maintenance and cleaning

.

Accessories

Repair
Please only send devices in for repair that have been cleaned
and are free of materials which might present health hazards.
For this, use the "certificate of compliance" form which you can ob-
tain from IKA
®
or can download a version for printing from the IKA
website at www.ika.com.
If your appliance requires repair, return it in its original packaging. Sto-
rage packaging is not sufficient when sending the device - also use ap-
propriate transport packaging.
Safety lift
The safety lift must be checked daily prior to operation!
After a long period of inactivity (approx. four weeks), use the motor to
move the lift to the top or bottom position several times prior to starting
distillation. (See the section entitled Safety Instructions - Safety Lift)! If the
safety lift is not working, please contact the IKA
RV 10.1
NS 29/32 Vertical glassware (1)
RV 10.10
NS 29/32 Vertical glassware, coated (1)
RV 10.2
NS 29/32 Diagonal glassware (2)
RV 10.20
NS 29/32 Diagonal glassware, coated (2)
RV 10.700
NS 29/42 Vertical glassware (1)
RV 10.710
NS 29/42 Vertical glassware, coated (1)
RV 10.800
NS 29/42 Diagonal glassware (2)
RV 10.810
NS 29/42 Diagonal glassware, coated (2)
RV 10.900
NS 24/40 Vertical glassware (1)
RV 10.910
NS 24/40 Vertical glassware, coated (1)
RV 10.1000
NS 24/40 Diagonal glassware (2)
RV 10.1010
NS 24/40 Diagonal glassware, coated (2)
RV 10.3
Vertical-intensive condenser with manifold(1)
RV 10.30
Vertical-intensive condenser with manifold, coated (1)
RV 10.4
Dry ice condenser (2)
RV 10.40
Dry ice condenser, coated (2)
RV 10.5
Vertical-condenser with manifold and cut-off valve (no picture)
RV 10.50
Vertical-condenser with manifold and cut-off valve, coated (no picture)
RV 10.6
Vertical-intensive condenser with manifold and cut-off valve
for reflux distillation (3)
RV 10.60
Vertical-intensive condenser with manifold and cut-off valve
for reflux distillation (3)
HB 10.1
Protection shield (Heating bath HB 10) (1)
HB 10.2
Protection cover (Heating bath HB 10) (2)
RV 10.70
NS 29/32 Steam pipe
RV 10.71
NS 24/29 Steam pipe
RV 10.72
NS 29/42 Steam pipe
RV 10.73
NS 24/40 Steam pipe
RV 10.74
NS 29/32 Steam pipe, short,
for reflux distillation
RV 10.75
NS 24/29 Steam pipe, short,
for reflux distillation
RV 10.76
NS 29/42 Steam pipe, short,
for reflux distillation
RV 10.77
NS 24/40 Steam pipe, short,
for reflux distillation
®
Service department.
®
65

Publicidad

Tabla de contenido
loading