GENERAL DESCRIPTION

Local push-button

The audio/video module can be equipped with an external local push-button (potential-
free), which can be configured to activate the electro-lock and the local relay.

Local relay output

There are two options for configuring the module relay output:
• active during a call
• active at the same time as the electro-lock
The first function is useful for activating an external light, if installed, to illuminate the
person during the entire call. When the call is complete, this output remains active for
a period of time set by the DIP switches.
The second function is used to activate any outdoor lock or for an auxiliary command.
The output is activated by the local push-button or the apartment unit opening push-
button. The duration of the relay closure is timed by the DIP switch.
The relay output is a NO, potential free type (comply with the technical data for this
output).