Installation Instructions
Please Read Before Installing
Table 1 - Models and Ratings
L L o o a a d d
M M o o d d e e l l # #
T T y y p p e e s s
1 1
HW-RPM-4A-120
INC, MLV,
ELV, NCC
HW-RPM-4A-230
INC, MLV,
ELV, NCC
2 2
HW-RPM-4E-120
ELV, INC
HW-RPM-4E-230-CE
2 2
ELV, INC
HW-RPM-4FSQ-120
3 3
FAN
MOTOR
HW-RPM-4U-120
INC, MLV,
NCC, F2W
HW-RPM-4U-230-CE
INC, MLV,
NCC, SFL
HW-RPM-4U-240
INC, MLV,
NCC, SFL
INC: Incandescent
MLV: Magnetic Low Voltage
NCC: Neon/Cold-Cathode F2W: Lutron Fluorescent Tu-Wire
1 1 . . For higher wattages or for load types other than those listed, a Power Booster or Interface is
required. See the HomeWorks Technical Reference Guide (P/N 366-963 for 120 V
for 220-240 V
) for details.
2 2 . . The HW-RPM-4E module is only to be used with electronic low-voltage type transformers. Use
with standard magnetic low-voltage transformers may damage the module and void the warranty.
3 3 . . The HW-RPM-4FSQ-120 provides quiet fan speed control for up to four ceiling fans (one fan per
circuit). This module cannot control fans that have integrated fan speed controls (i.e., any fan that
has a remote control). It is normal for the HW-RPM-4FSQ-120 module to hum or buzz when at the
medium-high fan speed setting. Do not connect this module to lighting loads. Damage to the mod-
ule could result.
Installation
1. Turn power off to all feeds to the panel.
Danger - The panel may be fed by multiple circuits.
Locate and lock each supply circuit breaker in the off
position before proceeding.
2. Mount the module into the rough-in panel.
Start with position 1, then 2, then 3, etc. Do not overtighten
screws, torque to 2.25 N
m (20 in.-lbs.) maximum (see
Figure 1).
Note - Install modules only in a HomeWorks Panel. To
determine which panels will accept modules, see the
HomeWorks Technical Reference Guide (P/N 366-963
for 120 V , 367-1029 for 220-240 V )
3. Install the module's wires into the appropriate terminal
blocks and secure using 0.6 N
NOT overtighten (see Figure 1).
4. Connect the control harness (provided with the HomeWorks
processor or Module Interface) to the module at the four-pin
connector.
V V o o l l t t a a g g e e / /
M M i i n n . .
M M a a x x . . L L o o a a d d
1 1
F F r r e e q q . .
L L o o a a d d
O O u u t t p p u u t t M M o o d d u u l l e e
120 V
10 W
10 A
16 A
50/60 Hz
220-240 V
10 W
8 A
13 A
50/60 Hz
120 V
25 W
9 A
16 A
50/60 Hz
(incl up to
2.5 A INC)
220-240 V
25 W
10 A
16 A
50/60 Hz
120 V
0.25 A
2 A
8 A
50/60 Hz
120 V
25 W
16 A
16 A
50/60 Hz
220-240 V
40 W
10 A
13 A
50/60 Hz
220-240 V
40 W
16 A
16 A
50/60 Hz
ELV: Electronic Low Voltage
SFL: Switched (non-dim) Fuorescent
®
, 367-1029
m of torque (5.25 in.-lbs.). DO
Remote Power Modules, 4 Circuits
HW-RPM-4A-120, HW-RPM-4A-230
HW-RPM-4E-120, HW-RPM-4E-230-CE
HW-RPM-4U-120, HW-RPM-4U-230-CE
HW-RPM-4U-240, HW-RPM-4FSQ-120
Note: This instruction sheet covers multiple Remote Power Module
model numbers, each with different voltages, load types, and ratings.
Please refer to Table 1 for more information.
Figure 1 - Remote Power Module Mounting
and Wiring
P P e e r r : :
6 Wires:
Circuit 1
Circuit 2
Circuit 3
Circuit 4
Hot/Live
Neutral
Load 2
5. Check that all bypass jumpers are installed. They will dis-
tribute power to each load and should not be removed until
after all modules and loads are fully installed and proven.
6. Turn on input feed circuit breakers and check that they
do not trip. Please refer to Table 1 for load type and capacity
for each model number.
Danger - Only turn on input feed circuit breakers when
load wiring is complete and it is safe to have power
applied.
Note (4FSQ only) - Verify that all connected fan loads
are functional. Use the fan's pull chain to set it to its
highest speed.
7. For any feed circuit breaker that trips, locate the shorted
load and resolve the wiring problem before proceeding.
8. Turn power OFF to all feeds to the panel.
This product may be covered under one or more of the following U.S. patents: 4,797,599;
4,889,999; 5,038,081; 5,170,068; 5,237,207; 6,046,550; 6,188,181; 6,380,693 and corre-
sponding foreign patents. U.S. and foreign patents pending. Lutron, HomeWorks, and the
sunburst logo are registered trademarks of Lutron Electronics Co., Inc.
© 2005 Lutron Electronics Co., Inc.
H H W W I I - - P P N N L L - - 5 5 P P a a n n e e l l S S h h o o w w n n
Label
4 Zone
Diagnostic LEDs
(4A only)
Unit Diagnostic
LED
Address Switch
4-Pin Connector
Five Position
Load 1
Bypass Jumper
Red 1
Red 2
Red 3
Red 4
Brn or Blk
Blu or Wht
Power Feed*
* Power Feed may be from external
breaker panel or from breaker within
panel enclosure (if so equipped).
Module
Interface

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Homeworks HW-RPM-4A-120

  • Página 1 1 1 . . For higher wattages or for load types other than those listed, a Power Booster or Interface is Brn or Blk required. See the HomeWorks Technical Reference Guide (P/N 366-963 for 120 V , 367-1029 Blu or Wht for 220-240 V ) for details.
  • Página 2: Technical Assistance

    1 blink per sec. Normal Operation "Heartbeat" (set module 1’s address switch to 1, etc.). 1 blink per 7 seconds Not communicating with proces- 14. After the HomeWorks Processor is programmed, check ® “lighthouse” sor: open control harness; mod- each module’s diagnostic LEDs (light emitting diodes). See ule set on invalid or diagnostic Tables 3 and 4.
  • Página 3: Instrucciones Para La Instalación

    1 1 . . Para potencias más altas o para otros tipos de carga que los listados, se requiere un Elevador Marr o Ngro o Interfaz de Potencia. Consulta la Guía de Referencia Técnica de HomeWorks (P/N 366-963 Az o Bco...
  • Página 4: Asistencia Técnica

    1 destello por segundo Operación Normal “Pulso” del módulo 1 en 1, etc.). 1 destello cada 7 segun- No hay comunicación con el pro- 14. Después que el Procesador HomeWorks esté programado, ® dos “faro” cesador: arnés de control abierto;...
  • Página 5 1 1 . . Pour puissance plus élevée ou pour types de charge autre que ceux listés, un amplificateur Bleu ou Blc de puissance ou Interface est requis. Voir le Guide de références techniques HomeWorks (P/N 366-963 pour 120 V , 367-1029 pour 220-240 V ) pour détails.
  • Página 6: Assistance Technique

    à 1, etc.). aux 7 sec. “phare” seur : ouvrir le harnais de contrôle; module est réglé à invalide ou adresse 14. Après la programmation du processeur HomeWorks , véri- ® de diagnostique; le système n’est pas fiez les DEL de diagnostique de chaque module (diodes configuré...
  • Página 7: Instruções De Instalação

    4,889,999; 5,038,081; 5,170,068; 5,237,207 e pelas patentes correspondentes no exterior. Há patentes pendentes nos EUA e em outros países. Lutron, GRAFIK Eye, HomeWorks e o logo de um sol entre nuvens são marcas comerciais registradas da Lutron Electronics Co., Inc.
  • Página 8 à posição do modulo (defina a switch de endereço do definido em endereço inválido ou módulo 1 como 1, etc.). de diagnóstico; sistema não foi con- 14. Após a programação do processador HomeWorks , veri- figurado ou endereçado adequada- ®...

Este manual también es adecuado para:

Hw-rpm-4a-230Hw-rpm-4e-120Hw-rpm-4e-230-ceHw-rpm-4u-120Hw-rpm-4u-230-ceHw-rpm-4u-240 ... Mostrar todo

Tabla de contenido