Descargar Imprimir esta página

B - The Options; Separation Kit; Remote Panel; Semi-Automatic Rinsing - Aqua-Base XD Serie Manual De Utilización

Publicidad

Idiomas disponibles

Idiomas disponibles

1 – SEPARATION KIT
This extra insures installation of the R/O module, being separated from the main module.
Assembling.
The R/O module is installed using the supplied
supports in any position, vertical or horizontal, as
long as the pressure valve is accessible and the
gauge is readable.
Connection.
- Connect the flexible hose (60) on the HP outlet of the pump, and on the R/O module inlet (Fig. 6p31). Tighten the fitting energetically with
two spanners.
Do not use watertight paste or Teflon during assembling of the HP flexible hose.
- Connect the HP hose on the pump and on the R/O module, tighten with a spanner (red marks),
- Connect the R/O module produced water outlet to the reject valve (10) inlet with a 8x10 tube (blue marks).
See the Installation drawing in ANNEXES page 46.
2 – REMOTE PANEL
This extra (Ref.821324-12 (12VCC) or Réf.821234-24 (24VCC)) insures control of the AQUA-BASE unit at a distance from the unit, chart
table, main electrical panel.
See the Chap A-3.4 page 18 of the manual.
3 – SEMI-AUTOMATIC RINSING
This option it's use for an easy flushing of the AQUA-BASE with water of the tank boat for regular maintenance.
Composition :
A box including :
- A actived carbon filter, a pump, a non-return valve, a minutor, pipes, connections, connecting cable.
Assembly, use :
- See the note delivered with the option.
B – THE OPTIONS
Composition.
Rep
Reference
60
712188-200
61
701079
62
717276
63
719107
J:\MANUEL-DOCUMENTATION\Projet manuels SLCE\1-SW PLAISANCE\AQUABASE XD\AQUABASE XD FRUKES 07-2007-A.doc
Description
Flexible hose 2m
Bracket
HP hose 8 X 13
HP hose 8 X 10
VERSION 2007-07-A
Qty
1
2
2 m
2 m
FR/UK/ES Page 21/50