Specific Operating Instructions
3
2
1
a.) Functional description of the energizer
Open the appliance by opening the closing cap (7) on both sides. Insert the accumulator into the bottom part, Lead out
the accumulator vent line (if present) through the cutout! When connecting the accumulator, be sure to observe the
correct polarities ( red + and black - ). Close the appliance again before putting it into service. Put the appliance into
service without fence and earth. If the fence light (4) flashes green, the appliance is ready for use. If in addition the
accumulator light (3) flashes red, check the accumulator for correct voltage. If the fence light (4) does not flash, check the
polarity of the connecting cable on the accumulator or have the appliance checked by a technician.
Operate the appliance only in vertical position and with closed lid, see above picture, right side!
b.) Functional description with connected fence system ( fence + earth )
Fence
Battery
light (4)
light (3)
flashes
flashes red
green
1
YES
NO
2
NO
NO
YES
3
YES
4
YES
NO
5
NO
YES
6
NO
NO
The colour code on the rotary knob (2) symbolises the current consumption for the shock power (e.g. green area:
reduced shock power with smaller current consumption; red: high shock power with increased current consumption).
If the fence light (4) flashes faster than approx. once per second, the appliance must be disconnected at once and
checked by a technician before it can be used again.
The accessories for this appliance are obtainable through specialised dealers!
Any user of electric fence systems is legally indebted to control the fence-appliance and the fence system regularly, in
accordance with the conditions of use, at least once per day.
-
visual check of the appliance and the fence system
measurement of the minimum voltage of 2500V at each point of the fence
-
Accessories/Tips:
The power source consists of wet-cell batteries: 12V, 50 Ah up to 12V, 100 Ah.
For maintenance-free operation, we recommend the use of a solar system.
With a mains adapter (with galvanic isolation), Item No.:44228, 230V operation is also possible.
Ensure a good grounding of the devices, with at least 3 ground rods, Item No.:44219 (Item No.:44375 for mobile use).
4
5
6
Possible current sources:
-12 Volt, 12 Volt+ solar, or
- 9 Volt, 9 Volt+ solar or
--230 Volt network operation
This energizer shall not be used as an  
animal trainer (inside a barn). 
Audible
clicks
> 3500 V = minimum requirement
YES
< 3500 V; use the rotary knob (2) to increase the power until
the fence light (4) starts flashing Attention: the higher this
YES
setting, the more current is consumed! If the green fence
light (4) still does not flash in the extreme position, see fault
finding in the enclosed instruction manual (Figure 2, p.5)!
> 3500 V = minimum requirement
YES
and:
< 3500 V; use the rotary knob (2) to increase the power until
the fence light (4) starts flashing. If it does not flash in the
YES
extreme position, see fault finding in the enclosed instruction
manual
(Figure 2, p.5)!
No pulses, in 12V operation the total discharge protection
NO
has been activated
see a.) Functional description of the appliance, without fence and earth
NO
7
Output voltage
3
TERRA 3
Solar / 230V mains adapter
1
connection + protective
cover
Rotary knob continuously
2
adjustable power control
Battery
3
indicator light
Fence voltage
4
indicator light
5 Earth connection
Fence connection
6
Closing cap
7
(used to close the top part
onto the bottom part!)
12V operation
OK (>12,2V)
OK (>12,2V)
Charge or
replace as soon
as possible
Charge or
replace as soon
as possible
Charge or
replace at once
-EN-
0,5 J
9V
operation
OK (>6V)
OK (>6V)
Replace as
soon as
possible
Replace as
soon as
possible
Replace at
once
Version : 2019.1