4 INSTALLATION
Electrical connections
The supply voltage is direct current 12V ±10% (12 VDC).
(The "compact" control panel has a 10A protection fuse).
Geoline control units can be supplied with a kit for electrical connection to the control panel, upon request.
To facilitate unit installation, it is supplied with a quick connection plug.
Connection cables:
a - Cable with a plug at one end and several leads at the other end for
connecting the control panel and the valve motors.
Cable not included with the control panel.
Various versions may be supplied (see table).
b - Intermediate cable with a plug at each end.
Cable included with the control panel.
Various versions may be supplied (see table).
c - Main power cable with plug at one end and
two free wires at the other end for connecting the
control panel and the 12V tractor battery.
This cable is supplied with the electric control
panel. This cable is already connected to the panel
in "compact" control panels.
An electrical plug for connection with the tractor
can also be supplied upon request.
P00801017_R05.indd 27
U s e
&
M a i n t e n a n c e
No. of ports
No. of ports
Cable length
2 - 3
3 m (10 ft)
5
3 m (10 ft)
2 - 3
3 m (10 ft)
5
3 m (10 ft)
b
c
M a n u a l
4
ENG
Cable length
2
3 m (10 ft)
2
5 m (16,5 ft)
3
3 m (10 ft)
3
5 m (16,5 ft)
5
3 m (10 ft)
5
5 m (16,5 ft)
Valves
independent
independent
dependent
dependent
04/02/2011 16.28.31
a
27