Possible Cause - Master Pumps MPXA08MRCALL Manual De Uso

Ocultar thumbs Ver también para MPXA08MRCALL:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

PROBLEM
1) THE ELECTROPUMP
DOES NOT PUMP WATER,
THE MOTOR DOES NOT RUN
2) THE MOTOR RUNS BUT
THE ELECTROPUMP DOES
NOT PUMP LIQUID
3) THE ELECTROPUMP
STOPS AFTER RUNNING
FOR A SHORT PERIOD OF
TIME BECAUSE ONE OF THE
THERMAL MOTOR CIRCUIT
BREAKER TRIPS
4) THE PUMP STARTS AND
STOPS TOO FREQUENTLY
5) THE ELECTROPUMP
DOES NOT REACH THE
DESIRED PRESSURE
6) THE ELECTROPUMP
DOES NOT RUN IN
CONTINUOUS MODE
If the problem persists despite the recommended corrective actions, contact the Customer Assistance Service:
sav@eco-repa.com

POSSIBLE CAUSE

1) No power.
2) Motor protection tripped.
3) Defective condenser.
4) Shaft blocked.
5) Pressure switch installed
incorrectly or damaged.
1) Empty pump body.
2) Air inlet from the suction pipe.
3) Suction height above the height
recommended for the unit.
1) The power supply does not
comply with the data on the
nameplate.
2) A solid object is blocking the
impellers.
3) The liquid is too thick.
4) The liquid or the environment are
too hot.
5) The pump is running without
fluids or the gate valve in the
suction pipe is closed.
1) The tank membrane is
damaged.
2) No compressed air in the
tank.
3) The foot valve on the suction
pipe is blocked and not
appropriately sealed.
1) The pressure required to stop
the pump pre-set on the pressure
switch is too low.
2) Air inlet from the suction pipe .
1) The maximum adjustment
of the pressure switch is too high.
2) Air inlet from the suction pipe.
2016 – Made in China
REMEDY
1) Verify that voltage is present and that
the plug has been correctly inserted.
2) Determine the cause of the problem
and reset the switch. If the thermal
switch has been enabled, wait for the
system to cool down.
3) Contact the Customer Assistance
Service.
4) Verify the cause and unblock the
electropump.
5) Contact the Customer Assistance
Service.
1)Stop the pump and fill the body with
water using the filling cap (fig. 1, n. 9).
2)Verify that: a) the joints are sealed - b)
the fluid level has not lowered below the
foot valve - c) the foot valve is sealed
and not blocked - d) there are no
siphons, bends, counter-slopes or
throats along the suction pipes.
3) Check and reduce the suction height
or use a device with more suitable
characteristics.
1) Check the voltage on the power
supply cable leads.
2) Disassemble and clean the
electropump.
3) Dilute the pumped fluid.
4-5) Remove the cause of the problem,
wait for the pump to cool down and
restart it.
1) Have the membrane or tank replaced
by qualified personnel.
2) Fill the tank with air using the delivery
valve and a maximum pressure of 1.5
bar.
3) Disassemble and clean the valve or
replace it when necessary.
1) Contact the Customer Assistance
Service.
2) See point 2.2.
1) Contact the Customer
2) See point 2.2.
23

Publicidad

Tabla de contenido
loading

Tabla de contenido