Air Driven Liquid Pump 4B Series • OM-16S
J. Use a torque wrench to tighten all bolts evenly. Torque incrementally in a criss-cross pattern
to 15 ft.-Ibs.
K. With the outlet port pointing up, reinstall and center all parts in reverse order of their removal.
L. Tighten fitting to 50 ft.-Ibs.
5