15 Troubleshooting

Should the flash unit fail to function properly or meaningless content
appear on the flash unit display panel, switch the flash unit off with the
main switch
for approximately 10 seconds. Check the camera settings
and make sure the foot of the flash unit is mounted correctly in the
camera's accessory shoe.
Replace the batteries with new or freshly charged batteries.
The flash unit should function normally again once it is switched back on.
If this is not the case, contact your local dealer.
Below is a list of some of the problems that may occur when the flash unit is
used. For each item, possible causes and remedies for the problem are listed.
No maximum flash range indication appears on the display panel.
• There has been no exchange of data between the flash unit and the camera.
Tap the camera's shutter release.
• The main reflector is not in normal position.
The AF measuring beam of the flash unit is not activated.
• The flash unit is not ready for firing.
• The camera is not in „ONE SHOT" mode.
• The camera supports only its own internal AF measuring beam.
• Some cameras support the AF measuring beam in the flash unit only with the
camera's central AF sensor. If a peripheral AF sensor is selected, then the
AF measuring beam will not be activated in the flash unit.
Activate the central AF sensor.
The reflector position is not automatically adjusted to the current
zoom position of the lens.
• The camera does not transfer data to the flash unit
• There is no exchange of data between the flash unit and the camera.
Tap the camera's shutter release.
• The camera is equipped with a lens without CPU.
• the flash unit operates in manual zoom mode „MZoom".
Switch to Auto-Zoom (see 9.1).
• The main reflector is swivelled out of its locked normal position.
• The wide-angle diffuser folds out from the main reflector.
• A Mecabounce is mounted in front of the main reflector.
The aperture setting on the flash unit is not automatically adjusted
to that of the lens.
• The camera does not transfer data to the flash unit
• There is no exchange of data between the flash unit and the camera.
Tap the camera's shutter release.
• The camera is equipped with a lens without CPU.
The indicator for the zoom position of the main reflector is blinking
on display panel
• Warning of shadowing on the edge of the image: the focal length set on the
camera lens (converted to the 35 mm format, 24x36) is shorter than the
adjusted zoom position of the main reflector.
TTL
The E
flash mode cannot be set.
• data transfer has not occurred between the flash unit and the camera.
Actuate shutter release.
TTL
• the camera does not support E
flash mode.